A Distance Detector with a Strip Magnetic MOSFET and Readout Circuit

نویسندگان

  • Guo-Ming Sung
  • Wen-Sheng Lin
  • Hsing-Kuang Wang
چکیده

This paper presents a distance detector composed of two separated metal-oxide semiconductor field-effect transistors (MOSFETs), a differential polysilicon cross-shaped Hall plate (CSHP), and a readout circuit. The distance detector was fabricated using 0.18 μm 1P6M Complementary Metal-Oxide Semiconductor (CMOS) technology to sense the magnetic induction perpendicular to the chip surface. The differential polysilicon CSHP enabled the magnetic device to not only increase the magnetosensitivity but also eliminate the offset voltage generated because of device mismatch and Lorentz force. Two MOSFETs generated two drain currents with a quadratic function of the differential Hall voltages at CSHP. A readout circuit-composed of a current-to-voltage converter, a low-pass filter, and a difference amplifier-was designed to amplify the current difference between two drains of MOSFETs. Measurements revealed that the electrostatic discharge (ESD) could be eliminated from the distance sensor by grounding it to earth; however, the sensor could be desensitized by ESD in the absence of grounding. The magnetic influence can be ignored if the magnetic body (human) stays far from the magnetic sensor, and the measuring system is grounded to earth by using the ESD wrist strap (Strap E-GND). Both 'no grounding' and 'grounding to power supply' conditions were unsuitable for measuring the induced Hall voltage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The OPAL Silicon Strip Microvertex Detector with Two Coordinate Readout

The OPAL experiment at the CERN LEP collider recently upgraded its silicon strip microvertex detector from one coordinate readout ( only) to two coordinate readout ( and z). This allows three dimensional vertex reconstruction and should improve lifetime measurements as well as b quark jet identi cation. This paper describes the new microvertex detector system with emphasis on the novel techniqu...

متن کامل

Status Report “Development of Short-Strip Silicon Detectors and Hybrids and a Frontend Readout ASIC”

• Identification of the optimum technology and layout of the tracking detectors for the upgraded ATLAS ID and construction of a short-strip silicon detector (SSD) module with sufficient radiation hardness for the intermediate and outer tracking region in the upgraded ATLAS ID. • Evaluation of integrated circuit technologies for the readout of the upgraded ATLAS ID, in particular the evaluation ...

متن کامل

Design and Construction of a Sensitive Capasitive Sensor System (RESEARCH NOTE)

Design and construction of a capacitor sensor with a precise readout system are described in this paper. A variable air-gap capacitive transducer was constructed and for signalmeasurement a successful attempt was made to exploit the capacitance changes in terms of the phase angle of the detected signal. The reported setup makes it possible to detect capacitance changes of the order of 2.5 fF in...

متن کامل

A control and readout system for the BELLE silicon vertex detector

A newly developed system for the control and readout of the BELLE silicon vertex detector (SVD) is described. The system is designed to meet the mechanical, electrical, and thermal requirements imposed by the BELLE detector. Its primary purpose is the ampli"cation of analog signals from the VA1 front-end integrated circuits, which are used to read the silicon-strip detectors. It also provides a...

متن کامل

Investigation of surface and buildup region doses for 6 MV high energy photon beams in the presence of a thermoplastic mask

Background: The accuracy and the reproducibility of radiotherapy can be provided by using immobilization devices such as thermoplastic masks. In head and neck cancer radiotherapy, the patients are mostly immobilized by using thermoplastic masks. In this study, the effect of the thermoplastic mask to the surface and buildup region doses was investigated by using Markus parallel plate ion chamber...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017