Design and Optimization Methodology of Sub-dermal Electroencephalography Dry Spike-Array Electrode
نویسندگان
چکیده
I hereby declare that I am the sole author of this thesis. This is a true copy of the thesis, including any required final revisions, as accepted by my examiners. I understand that my thesis may be made electronically available to the public. Abstract Monitoring bio-electric events is a common procedure, which provides medical data required in clinical and research applications. Electrophysiological measurements are applied in diagnosis as well as evaluation of the performance of different body organs and systems, e.g. the heart, muscles and the nervous system. Furthermore, it is staple feature in operation rooms and extensive care units. The performance of the recording system is affected by the tools and instrumentation used and the bio-electrode is a key-player in electrophysiology, hence, the improvements in the electrode recording technique will be directly reflected in the system's performance in terms of the signal quality, recording duration as well as patient comfort. In this thesis, a design methodology for micro-spike array dry bio-electrodes is introduced. The purpose of this methodology is to meet the design specifications for portable long-term EEG recording and optimize the electrical performance of the electrodes by maximizing the electrode-skin contact surface area, while fulfilling design constraints including mechanical, physiological and economical limitations. This was followed by proposing a low cost fabrication technique to implement the electrodes. The proposed electrode design has a potential impact in enhancing the performance of the current recording systems, and also suits portable monitoring and long term recording devices. The design process was aided by using a software design and optimization tool, which was specifically created for this application. The application conditions added challenges to the electrode design in order to meet the required performance requirements. On the other hand, the required design specifications are not fulfilled in the current electrode technologies which are designed and customized only for short term clinical recordings. The electrode theory of application was verified using an experimental setup for an electrochemical cell, but the overall performance including measuring the electrode impedance is awaiting a clinical trial. iv Acknowledgements
منابع مشابه
Adsorption study of Zinc ion onto halloysite nanotubes using taguchi’s design of experimental methodology
In this paper, Taguchi method was applied to determine the optimum conditions for Zn (II) removal from aqueous solution by halloysite nanotubes (HNTs). An orthogonal array experimental design (L16 (45) which is of five control factors including pH, t (contact time), m (adsorbent mass), T (temperature) and C0 (initial concentration of Zn (II)) having four levels ...
متن کاملAdsorption study of Zinc ion onto halloysite nanotubes using taguchi’s design of experimental methodology
In this paper, Taguchi method was applied to determine the optimum conditions for Zn (II) removal from aqueous solution by halloysite nanotubes (HNTs). An orthogonal array experimental design (L16 (45) which is of five control factors including pH, t (contact time), m (adsorbent mass), T (temperature) and C0 (initial concentration of Zn (II)) having four levels ...
متن کاملFlexible Electrode Array for Retinal Stimulation
In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...
متن کاملDeveloping Barbed Microtip-Based Electrode Arrays for Biopotential Measurement
This study involved fabricating barbed microtip-based electrode arrays by using silicon wet etching. KOH anisotropic wet etching was employed to form a standard pyramidal microtip array and HF/HNO3 isotropic etching was used to fabricate barbs on these microtips. To improve the electrical conductance between the tip array on the front side of the wafer and the electrical contact on the back sid...
متن کاملA dry electrode for EEG recording.
This paper describes the design, fabrication and testing of a prototype dry surface electrode for EEG signal recording. The new dry electrode has the advantages of no need for skin preparation or conductive paste, potential for reduced sensitivity to motion artifacts and an enhanced signal-to-noise ratio. The electrode's sensing element is a 3 mm stainless steel disk which has a 2000 A (200 nm)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2006