Temperature control is a key factor which affects the construction quality of the mass concrete, which is also an important measure to prevent crack propagation. Lots of engineering practices show that most of temperature cracks come out in the form of the surface crack during the construction of the concrete dam. In addition, deep cracks and transverse cracks are usually developed by surface cracks. Strengthening conversation and surface insulation are one of the main methods to prevent surface cracks. In this paper, Xiluodu hydropower dam is taken as the engineering background, and an insulation monitoring experiment under the winter low-temperature condition was carried out on the fresh concrete layer during the construction period using the distributed fiber optic temperature monitoring system. The inversion of the equivalent heat coefficient for the fresh concrete layer with the covering of the polyethylene membrane insulation materials was conducted, besides the monitoring results and the feedback analysis of the conservation status was obtained based on the test data. The above procedure provides a basis for evaluating the quality of construction and the dynamic adjustment of the construction programs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Application of a Photoacoustic Sensor for Monitoring the Laser Generated Stress Waves in Optical Fiber

Measurement of stress transients generated by a 400ns pulsed HF laser in an infrared fluoride glass fiber has been made using fast time – response piezoelectric film transducer. Acoustic signals up to 12 mV with frequencies ranging in megahertz generated by 21 mJ laser pulse when passed through the fiber axis in the linear region. It is shown that useful information such as onset of non - linea...

متن کامل

Propose of a novel method to simulate and optimize a polymer optical fiber daylighting system

Optical fiber day lighting systems help the efficiency of using solar energy in the lighting system in domestic, industrial and agricultural sectors. A lot of work has been done on these systems, but the lack of a reliable simulation method to reduce the tolerance, time and cost is evident. In this regard, in this paper, a novel method based on two powerful Optifiber and Zemax software has bee...

متن کامل

Influence of High Temperatures on Flexural Strength of Foamed Concrete Containing Fly Ash and Polypropylene Fiber

In this study, the elevated temperature flexural strengths of lightweight foamed concrete (LFC) containing fly ash (FA) and polypropylene fiber (PF) was investigated experimentally and statistically. The variables included were the temperature degrees (in a range of 20 to 600°C), LFC densities of 600, 800, 1000, 1200 and 1400 kg/m3 and additive content. Two mixes were made by replacing 15% and ...

متن کامل

Detection of Fuel Adulteration in Real Time Using Optical Fiber Sensor and Peripheral Interface Controller

Detection of fuel adulteration in real time is the most important need of the world as it generates the hazardous effects on the environment, living and nonliving things. Various automotive users and fuel providers may mix kerosene in petrol and diesel. Adulterated fuel increases air pollution, as well as reduces the performance of vehicle engines. Such a malpractice in fuel is prevailing becau...

متن کامل

Experimental investigation of the strength of glass fiber-reinforced concrete exposed to high temperature

This study investigated the effects of high temperature exposure on the compressive, tensile, and flexural strengths of concrete containing glass fiber. A total of 108 cubic specimens (150 mm × 150 mm × 150 mm), cylindrical specimens (300 mm × 150 mm), and prismatic specimens (500 mm × 150 mm × 150 mm) were prepared for compressive, tensile, and flexural strength testing, respectively. The spec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015