Grade 1 spondylolisthesis and interspinous device placement: removal in six patients and analysis of current data

نویسندگان

  • Parker E. Bohm
  • Karen K. Anderson
  • Elizabeth A. Friis
  • Paul M. Arnold
چکیده

BACKGROUND In the treatment of patients with Grade 1 spondylolisthesis, the use of interspinous devices has been controversial for nearly a decade. Several authors have suggested that Grade 1 spondylolisthesis be considered a contraindication for interspinous device placement. METHODS We removed interspinous devices in six symptomatic Grade 1 spondylolisthesis patients and analyzed pertinent literature. RESULTS All six patients reported an improvement in symptoms following device removal and subsequent instrumented fusion. One patient who had not been able to walk due to pain regained the ability to walk. Several articles were identified related to spondylolisthesis and interspinous devices. CONCLUSIONS Regarding patients receiving interspinous devices for symptomatic lumbar spinal stenosis, several high-quality studies have failed to demonstrate a statistical difference in outcomes between patients with or without Grade 1 spondylolisthesis. Nevertheless, surgeons should have a high degree of suspicion when considering use of interspinous devices in this patient population.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

شکست وسایل تثبیت ستون فقرات

This was a retrospective review of a consecutive series of patients with spinal disease in year 2000, who underwent posterior fusion and instrumentation with Harrington distraction and Cotrel-Dobousset system to evaluate causes of hardware failure. Many cases of clinical failure has been observed in spinal instrumentation used in spinal disorder like spondylolisthesis, fractures, deformities, …...

متن کامل

Interspinous process decompression with the X-STOP device for lumbar spinal stenosis: a 4-year follow-up study.

X-STOP is the first interspinous process decompression device that was shown to be superior to nonoperative therapy in patients with neurogenic intermittent claudication secondary to spinal stenosis in the multicenter randomized study at 1 and 2 years. We present 4-year follow-up data on the X-STOP patients. Patient records were screened to identify potentially eligible subjects who underwent X...

متن کامل

Clinical Outcomes of a Polyaxial Interspinous Fusion System

BACKGROUND Early interspinous process fixation constructs utilize rigid fixation plates with immobile spikes which increase the difficulty of device implantation when anatomic variations are encountered. Second generation systems have been designed with polyaxial properties with the goal of accommodating natural osseous anatomic variations to achieve optimal implant placement and fixation integ...

متن کامل

A Novel Nonpedicular Screw-Based Fixation in Lumbar Spondylolisthesis

Objective. The authors present the clinical results obtained in patients who underwent interspinous fusion device (IFD) implantation following posterior lumbar interbody fusion (PLIF). The purpose of this study is investigating the feasibility of IFD with PLIF in the treatment of lumbar spondylolisthesis. Methods. Between September 2013 and November 2014, 39 patients underwent PLIF and subseque...

متن کامل

Curb the Pain of Spondylolisthesis; Comparing Posterolateral Fusion with Posterior Lumbar Interbody Fusion

Background & Aim: The purpose of this study was to evaluate and compare the pain of patients with spondylolisthesis who had undergone either of the surgery techniques: posterolateral fusion (PLF) or posterior lumbar interbody fusion (PLIF). Methods & Materials/Patients: In a prospective observational study, 102 surgical candidates with low grade degenerative and isthmic spondylolisthesis were e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2015