Evaluation of PIMA Point-of-care CD4 Analyzer in Yunnan, China
نویسندگان
چکیده
BACKGROUND CD4 count is used to determine antiretroviral therapy (ART) eligibility. In China, flow cytometers are mostly located in urban areas with limited access by patients residing in remote areas. In an attempt to address this issue, we conducted a study to validate the performance of Alere PIMA point-of-care CD4 analyzer. METHODS Venous and finger-prick blood specimens were collected from HIV-positive participants from two voluntary counseling and testing sites in Yunnan Province. Both venous and finger-prick blood specimens were tested with the PIMA analyzer. Venous blood specimens tested with the Becton Dickinson FACSCalibur were used as a reference. RESULTS Venous specimens from 396 and finger-prick specimens from 387 persons were available for analysis. CD4 counts by PIMA correlated well with those from FACSCalibur with an R2 of 0.91 for venous blood and 0.81 for finger-prick blood. Compared to FACSCalibur, the PIMA analyzer yielded lower counts with a mean bias of - 47.0 cells/μl (limit of agreement, [LOA]: -204-110 cells/μl) for venous blood and -71.0 cells/μl (LOA: -295-153 cells/μl) for finger-prick blood. For a CD4 threshold of 350 cells/μl, the positive predictive value (PPV) of PIMA was 84.2% and 75.7% and the negative predictive value (NPV) was 97.6% and 95.8% for venous and finger-prick blood, respectively. For an ART threshold of 500 cells/μl, the corresponding PPV was 90.3% and 84.0% and NPV was 94.3% and 93.4%, respectively. CONCLUSIONS CD4 counting using venous blood with PIMA analyzers is a feasible alternative to a large flow cytometer to determine ART eligibility.
منابع مشابه
Utility of the point of care CD4 analyzer, PIMA, to enumerate CD4 counts in the field settings in India
UNLABELLED BACKGROUND In resource limited settings non-availability of CD4 count facility at the site could adversely affect the ART roll out programme. Point of care CD4 enumerating equipments can make the CD4 count available at the site of care and improve the patients' management considerably. This study is aimed at determining the utility of a Point of Care PIMA CD4 analyzer (Alere, Germ...
متن کاملEvaluation of the PIMA point-of-care CD4 analyzer in VCT clinics in Zimbabwe.
Point-of-care (POC) CD4 testing was implemented at a stand-alone HIV voluntary testing and counseling centre in Harare, Zimbabwe. To validate the use of this new technology, paired blood samples were collected from 165 patients either by a nurse or a laboratory technician and tested using POC and conventional laboratory CD4 machines. Finger prick (capillary) blood was collected directly into th...
متن کاملField Evaluation of a Point-of-Care CD4 Analyzer for Monitoring HIV Patients in the Interior of the Amazon Region, Brazil
OBJECTIVE To evaluate the accuracy of the PIMA point-of-care CD4 analyzer (PIMA) under field conditions in comparison to the current CD4 count system (FACSCalibur), and to evaluate the operational suitability and acceptability of health professionals (HP) and HIV-patients in using the PIMA in health clinics in the Amazon Region. METHODS CD4 counts were measured onsite by the PIMA using finger...
متن کاملEvaluation of Portable Point-of-Care CD4 Counter with High Sensitivity for Detecting Patients Eligible for Antiretroviral Therapy
BACKGROUND Accurate, inexpensive point-of-care CD4+ T cell testing technologies are needed that can deliver CD4+ T cell results at lower level health centers or community outreach voluntary counseling and testing. We sought to evaluate a point-of-care CD4+ T cell counter, the Pima CD4 Test System, a portable, battery-operated bench-top instrument that is designed to use finger stick blood sampl...
متن کاملPIMA Point of Care CD4+ Cell Count Machines in Remote MNCH Settings: Lessons Learned from Seven Districts in Zimbabwe
An evaluation was commissioned to generate evidence on the impact of PIMA point-of-care CD4+ count machines in maternal and new-born child health settings in Zimbabwe; document best practices, lessons learned, challenges, and recommendations related to scale up of this new technology. A mixed methodology approach that included 31 in-depth interviews with stakeholders involved in procurement, di...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 128 شماره
صفحات -
تاریخ انتشار 2015