Measurement of infarct size and percentage myocardium infarcted in a dog preparation with single photon-emission computed tomography, thallium-201, and indium 111-monoclonal antimyosin Fab.

نویسندگان

  • L L Johnson
  • K S Lerrick
  • J Coromilas
  • D W Seldin
  • P D Esser
  • J M Zimmerman
  • A M Keller
  • P O Alderson
  • J T Bigger
  • P J Cannon
چکیده

Single photon-emission tomography (SPECT) and indium 111-labeled monoclonal antimyosin Fab fragments were used to measure myocardial infarct size in 12 dogs, six subjected to balloon catheter-induced coronary artery occlusion for 6 hr (late reperfusion) and six subjected to occlusion with reperfusion at 2 hr (early reperfusion). Tomographic imaging was performed 24 hr after the intravenous injection of labeled Fab fragments with the use of a dual-head SPECT camera with medium-energy collimators. Immediately after the first tomographic scan, thallium-201 was injected into nine of 12 dogs and imaging was repeated. Estimated infarct size in grams was calculated from transaxially reconstructed, normalized, and background-corrected indium SPECT images with the use of a threshold technique for edge detection. Estimated noninfarcted myocardium in grams was calculated from obliquely reconstructed thallium SPECT images by a similar method. The animals were killed and infarct size in grams and true infarct size as a percentage of total left ventricular myocardial volume were measured by triphenyl tetrazolium chloride staining. Estimated infarct size from indium SPECT images showed an excellent correlation with true infarct size (r = .95, SEE = 4.1 g). Estimated percentage myocardium infarcted was calculated by dividing estimated infarct size from indium images by the sum of estimated infarct size plus estimated noninfarcted myocardium obtained from thallium images. Correlation between the estimated percentage of myocardium infarcted and true percentage of myocardium infarcted was excellent (r = .93, SEE = 4.4%). We conclude that dual-isotope SPECT with indium 111-monoclonal antimyosin antibodies and thallium-201 can accurately estimate infarct size and percentage myocardium infarcted.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurement of infarct size and percentage myocardium infarcted in a dog preparation with single photon - emission computed tomography , thallium - 201 , and indium 111 - monoclonal antimyosin

Single photon-emission tomography (SPECT) and indium 1ll-labeled monoclonal antimyosin Fab fragments were used to measure myocardial infarct size in 12 dogs, six subjected to balloon catheter-induced coronary artery occlusion for 6 hr (late reperfusion) and six subjected to occlusion with reperfusion at 2 hr (early reperfusion). Tomographic imaging was performed 24 hr after the intravenous inje...

متن کامل

Measurement of infarct size and percentage myocardium infarcted in a dog preparation with single photon - emission computed tomography , thallium - 201 , and indium 111 - monoclonal

Single photon-emission tomography (SPECT) and indium 1ll-labeled monoclonal antimyosin Fab fragments were used to measure myocardial infarct size in 12 dogs, six subjected to balloon catheter-induced coronary artery occlusion for 6 hr (late reperfusion) and six subjected to occlusion with reperfusion at 2 hr (early reperfusion). Tomographic imaging was performed 24 hr after the intravenous inje...

متن کامل

Dual isotope thallium and indium antimyosin SPECT imaging to identify acute infarct patients at further ischemic risk.

Forty-two patients (28 men and 14 women) with acute myocardial infarction (35 Q, seven non-Q wave) were injected with 2.0 mCi indium 111-labeled antimyosin (AM) monoclonal antibody (111In AM) within 48 hours of the onset of chest pain. Forty-eight hours later (72-96 hours after onset of chest pain), patients were injected with 2.2 mCi thallium 201, and two sets of single-photon emission compute...

متن کامل

Quantification of myocardial infarct size by thallium-201 single-photon emission computed tomography: experimental validation in the dog.

To evaluate the potential advantages of thallium-201 (201T1) single-photon emission computerized tomography (SPECT) to assess myocardial infarct size in the experimental animal, six normal dogs and 14 dogs with 6 to 8 hr closed-chest coronary occlusion (eight left anterior descending and six left circumflex) were studied. Ten minutes after intravenous administration of 2 mCi of 201T1, 30 projec...

متن کامل

New method of estimating myocardial infarct size using technetium-99m pyrophosphate and thallium-201 dual single photon emission computed tomography imaging.

A new method was devised to estimate infarct size using dual single photon emission computed tomography with thallium-201 and technetium-99m pyrophosphate. Designating the ratio of infarct area to whole myocardial volume as %MI, the correlation of %MI with other markers of left ventricular dysfunction was examined: peak creatine kinase, ejection fraction and left ventricular asynergy. As %MI co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 76 1  شماره 

صفحات  -

تاریخ انتشار 1987