The fine anatomical detail visible in computed tomography (CT) images has revolutionized diagnosis of both acute and chronic diseases and often provides information critical to the management and planning of treatment for both adults and children. As technological advances have increased, the range of examinations CT utilization has steadily increased and has recently been reported to be as high as 17% of the total radiology workload. However, the x-ray exposure from each CT scan is substantially higher (2-15 mSv) than plain film radiography (0.05-2 mSv) and, therefore, CT accounts for about 70-75% of the total ionizing radiation from diagnostic imaging. While these levels of radiation are well below those that cause deterministic effects (for example, cell death), there is concern that they may be associated with a risk of stochastic effects (such as cancer), albeit small.
منابع مشابه
Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...
متن کاملThyroid dose and dose reduction method from CT scan of head and neck
Introduction: Computed tomography (CT) consists of 11% of all imaging methods, but accounts for approximately 67% of radiation exposure due to diagnostic cases. More than one-third of all CT scans are done in the head and neck area. The thyroid gland is irradiated during CT head and neck. According to studies, this gland has the highest levels of radiation-induced cancer, and i...
متن کاملClinical Value of Low Dose CT- Scan in Pediatric Chest Diseases: Adequacy Assessment
Background Radiation dose about 400 times that of standard thoracic computed tomography (CT) in comparison with chest X- ray resulting in different approaches to decrease radiation dose have been established in the last few years to prevent possible side effects especially in children, such as low dose protocols. The aim of this study was assessment of clinical v...
متن کاملEvaluation of Occupational Radiation Dose in One Year for Operators Working in CT Scan Centers
Introduction: Becuase of the most radiation dose receiving by human is related to medical radiation exposures, and also Computed Tomography (CT) is a special type of radiography that is one of the main method of radiation exposure today, and it's growing increasingly. Therefore, radio technologists working in CT scan imaging centers, are at risk of radiation. Due to the high am...
متن کاملDiagnostic Reference Levels for Computed Tomography Examinations in Iran: A Nationwide Radiation Dose Survey
Introduction: International Commission on Radiological Protection introduced three basic principles of radiation protection, namely justification, optimization, and dose limit. Medical exposure has no dose limits, and generally, diagnostic reference levels are used as a tool for optimization of patient protection. Material and Methods: Dosimetry was performed on 20 CT scanners located in 14 cit...