Tissue Density Mapping of Cone Beam CT Images for Accurate Dose Calculations

نویسندگان

  • Bei Liu
  • Fritz A. Lerma
  • Jianzhou Wu
  • Byong Yong Yi
  • Cedric Yu
چکیده

Purpose: To improve the accuracy in megavoltage photon beam dose calculation in CBCT-based radiation treatment (RT) plans, using a kilovoltage cone-beam computed tomography (CBCT)-todensity-step (CBCT-SF) function. Materials and Methods: The CBCT-SF table is constructed from differential histograms of the voxel values of CBCT and Fan-beam CT (FBCT). From the CBCT histograms, frequency peaks representing air, lung, soft tissue and bone are observed and their widths in CT numbers are assigned to the lower and higher bounds of the steps in the CBCT-SF. The CBCT-SF is entered into a planning system as an alternative to the clinical CT-to-density table. The CT image sets studied in this work consist of FBCT and CBCT scans of three patients: a prostate cancer patient, a lung cancer patient and a head and neck patient; and of a humanoid phantom at sections of the pelvis, the thorax and the head. Deformable image registration is used to map the patient FBCT scans to the corresponding CBCT images to minimize anatomical variations. Threedimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT) plans are made on the FBCT image sets of the patients and the phantom. The plans are recalculated on the CBCT scans using both the conventional CT-to-density table and the CBCT-SF. Dose calculations on the CBCT images and FBCT images are compared using dose differences, distance to agreement (DTA), Gamma analyses and dose volume histogram (DVH) analyses. Results: The results show that IMRT plans optimized using CBCT scans and FBCT scans agree dosimetrically within 1% when the CBCT-SF is used for the CBCT-based plans, including thoracic IMRT plan. In contrast, up to 5% dose difference is observed between IMRT plans optimized on FBCT scans and CBCT scans for thoracic cases if conventional CT-to-density table is used on CBCT images. Conclusions: The simple stepwise mapping of the CBCT numbers to density using the CBCT-SF resolves the inaccuracies in dose calculations previously reported in CBCT-based RT plans. CBCT-SF can be used in ImageGuided adaptive radiotherapy planning.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shading correction for cone-beam CT in radiotherapy: Validation of dose calculation accuracy using clinical images

Cone-beam CT (CBCT) images are routinely acquired to verify patient position in radiotherapy (RT), but are typically not calibrated in Hounsfield Units (HU) and feature non-uniformity due to X-ray scatter and detector persistence effects. This prevents direct use of CBCT for re-calculation of RT delivered dose. We previously developed a prior-image based correction method to restore HU values a...

متن کامل

Evaluation of the gray level in CBCT systems and its relationship with HU in CT Scanners

Introduction: Cone-beam CT (CBCT) is an imaging system which offers three-dimensional (3D), multiplanar images and has many advantages over computed tomography (CT) including shorter acquisition times for the resolution desired in dentistry, lower radiation dose to the patient, reasonable price and higher spatial resolution but CBCT scanners are unable to display actual Hounsf...

متن کامل

A new tissue segmentation method to calculate 3D dose in small animal radiation therapy

BACKGROUND In pre-clinical animal experiments, radiation delivery is usually delivered with kV photon beams, in contrast to the MV beams used in clinical irradiation, because of the small size of the animals. At this medium energy range, however, the contribution of the photoelectric effect to absorbed dose is significant. Accurate dose calculation therefore requires a more detailed tissue defi...

متن کامل

Correlation Between Tissue Densities in Computed Tomography and Three Different Cone-Beam Computed Tomography Units (In Vitro)

Background and Aim: Bone density is of great assistance in the selection of the proper implant site. The present study aimed to assess the correlation between tissue densities in computed tomography (CT) and three different cone-beam computed tomography (CBCT) units. Materials and Methods: In this descriptive study, a radiographic phantom consisting of a transparent polymethyl methacrylate (PM...

متن کامل

Use of kilovoltage X-ray volume imaging in patient dose calculation for head-and-neck and partial brain radiation therapy

BACKGROUND To evaluate the accuracy of using kilovoltage x-ray cone-beam computed tomography (kV-CBCT) imaging for in vivo dose calculations. METHODS A Region-of-Interest (ROI) CT number mapping method was developed to generate the cone-beam CT number vs. relative electron density calibration curve for 3D dose calculations. The stability of the results was validated for three consecutive mont...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015