Stark width and shift measurements of visible Si III lines
نویسندگان
چکیده
A set of experimental Stark width and shift parameters of visible doubly ionized silicon spectral lines is reported in this paper. Measurements have been made on a pulsed plasma generated in a linear discharge lamp filled with a mixture of silane and helium. Electron density and temperature in this plasma range from 0.2 to 0.9 × 10 23 m −3 and from 17 500 to 21 000 K respectively. Electron density has been simultaneously determined by two-wavelength interferometry and from Stark broadening of He i 501.6 nm, He i 728.1 nm and H α lines. Temperature has been simultaneously determined from Boltzmann-plot of He i lines, from absolute emission of He i lines, from Boltzmann-plot of Si ii lines and from Si iii/Si ii intensities ratio. Dependencies of measured Stark parameters with electron density and temperature have been investigated and the final results have been compared with most of the previous experimental data as well as with some theoretical models.
منابع مشابه
QUADRATIC STARK CONSTANTS OF NEUTRAL COPPER SPECTRAL LINES IN THE COULOMB APPROXIMATION
Quadratic Stark constants of neutral copper spectral lines for all s,p, and d levels are calculated using the Coulomb approximation. These results are compared with existing data and, generally, good agreement is observed
متن کاملStark broadening experiments on a vacuum arc discharge in tin vapor.
Pinched discharge plasmas in tin vapor are candidates for application in future semiconductor lithography tools. This paper presents time-resolved measurements of Stark broadened linewidths in a pulsed tin discharge. Stark broadening parameters have been determined for four lines of the Sn III spectrum in the range from 522 to 538 nm, based on a cross-calibration to a Sn II line with a previous...
متن کاملShift and broadening of neutral helium spectral lines in dense plasmas
Shift and broadening of isolated neutral Helium lines 7281Å (2P − 3S), 6678Å (2P − 3D), and 4713Å (2P − 4S) in a dense plasma are investigated. Based on a quantum statistical theory using thermodynamic Green’s functions, where the electronic contributions to the shift and width are considered. Dynamical screening of the electron-atom interactions are included. Compared to the width, the electro...
متن کاملHydrogen Balmer Series Measurements in Laser- Induced Air Plasma
Time-resolved spectroscopy is employed to analyze micro plasma generated in laboratory air. Stark-broadened emission profiles for hydrogen alpha and beta allow us to determine plasma characteristics for specific time delays after plasma generation. Stark shift, asymmetry, and full width half maximum measurements are used to infer electron density. The measurements of hydrogen alpha and beta Bal...
متن کاملEmpirical Formulae for Electron Density Diagnostics from Hα and Hβ Line Profiles
We present empirical formulae for the electron density vs. line profile widths and shifts developed from precise measurements of hydrogen Balmer series alpha and beta emissions for diagnostics of laser-induced plasma. The formulae are for the Stark width and Stark red shift of the Hα line, as well as for the Stark width and peak separation of the Hβ line and are tested using measurements of Hα ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2000