[Haemostasis control during laparoscopic partial nephrectomy without parenchymal renorrhaphy: the VIVOSTAT(®) experience].
نویسندگان
چکیده
OBJECTIVE To present our experience using an autologous fibrin sealant prepared with the Vivostat system(®) to control haemostasis without any renal parenchymal reconstruction. MATERIAL AND METHODS We performed 45 laparoscopic partial nephrectomies using this haemostatic agent. The surgical steps were: colon mobilization, identification of ureter, renal vessels and renal tumor, renal artery control with Rummel tourniquet, tumor excision with harmonic scalpel, application of fibrin glue to the resection bed twice (before and after kidney reperfusion). Patients were evaluated for acute or delayed bleeding. RESULTS Mean age was 63.9 years (33-80); mean tumor size was 2.5cm (1.5-4); mean operative time was 136.1min (90-180). Mean warm ischemia time was 19.2min (10-30). Mean blood loss was 97ml (50-300). Individual haemostatic stitches were performed before application of the sealant if acute bleeding was observed (14 cases). We did not achieve any case of postoperative bleeding from resection bed or renal failure. 1 patient required transfusion due to an abdominal wall haematoma. 65% were clear cell carcinoma, 10% were papillary carcinoma, 20% were oncocitoma. Free margin rate was 100%. Mean hospital stay was 4 days (2-6). Mean follow-up was 14 months (5-45). CONCLUSIONS Excluding renorrhaphy during laparoscopic partial nephrectomy is feasible and safe. Our initial experience with the vivostat system in laparoscopic partial nephrectomy has been encouraging, but longer follow-up is needed to determine the real benefit of this surgical technique in laparoscopic partial nephrectomy.
منابع مشابه
SURGICAL TECHNIQUE Haemostasis control during laparoscopic partial nephrectomy without parenchymal renorrhaphy: The Vivostat experience
متن کامل
The clinical application of the sliding loop technique for renorrhaphy during robot-assisted laparoscopic partial nephrectomy: Surgical technique and outcomes
PURPOSE To report the initial clinical outcomes of the newly devised sliding loop technique (SLT) used for renorrhaphy in patients who underwent robot-assisted laparoscopic partial nephrectomy (RALPN) for small renal mass. MATERIALS AND METHODS We reviewed the surgical videos and medical charts of 31 patients who had undergone RALPN with the SLT renorrhaphy performed by two surgeons (CWJ and ...
متن کامل[Simplified renorrhaphy using self-retaining barbed suture during laparoscopic partial nephrectomy].
INTRODUCTION AND OBJECTIVES Laparoscopic partial nephrectomy (LPN) is a challenging procedure that requires quick and effective intracorporeal suturing, that could limit widespread adoption. Refinements of surgery have improved warm ischemia times and facilitated renal reconstruction. We present a technique that makes renorrhaphy easier using Self-Retaining Barbed Suture (SRBS) weaving two thre...
متن کاملFeasibility of Laparoendoscopic Single-Site Partial Nephrectomy in a Porcine Model
PURPOSE We performed laparoendoscopic single-site (LESS) partial nephrectomy in a porcine model with the objectives of overcoming the technical challenges of this surgery and exploring its feasibility. MATERIALS AND METHODS Six partial nephrectomies were performed on a pig aged 5 months, three cases on each kidney, by four surgeons: two urologists with much experience in laparoscopic surgery ...
متن کاملComparison of two different suture techniques in laparoscopic partial nephrectomy
OBJECTIVE To comparatively evaluate the traditional interrupted knot-tying and running suture renorrhaphy with Monocryl® in laparoscopic partial nephrectomy (LPN). MATERIALS AND METHODS A retrospective analysis of 62 consecutive patients undergoing LPN using traditional interrupted knot-tying suture renorrhaphy (Group 1; n=31) or running suture technique renorrhaphy with 2-0 monofilament poly...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Actas urologicas espanolas
دوره 37 1 شماره
صفحات -
تاریخ انتشار 2013