Comparison of two ELISA-based methods for the detection of microcystins in blood serum.

نویسندگان

  • Alexandra H Heussner
  • Isabell Winter
  • Stefan Altaner
  • Lisa Kamp
  • Fernando Rubio
  • Daniel R Dietrich
چکیده

Microcystins (MCs) are cyanobacterial toxins which place the public at risk via exposure to MC contaminated water, food or algal food supplements. Subsequent to the fatal intravenous exposure of dialysis patients in Caruaru, Brazil, several techniques (LC-MS, GC-MS and ELISA) were adapted to detect MCs in human serum. As patients chronically exposed to low concentrations of MCs also present with very low MC serum levels, only LC-MS methodology would appear to allow detection of these MC levels. However, LC-MS detection depends on the availability of respective MC congener standards and the levels of non-covalently bound MC in the sample. In contrast, immunological techniques, e.g. MC-ELISA potentially could detect even covalently bound MC, provided the MC-antibody was raised against an epitope found in nearly all of the MC congeners. As the Adda-side-chain moiety is present in nearly all of the MC congeners known to date, the anti-Adda antibodies, when applied in Adda-ELISAs, could represent a relatively simple and robust technique for the qualitative and quantitative determination of MC in human serum. The aim of the current study was to determine whether commercially available Adda-ELISAs and their respective sample preparation methods would allow MC quantification in human serum. The Adda-ELISA (polyclonal antibody) and the Adda-ELISA (monoclonal antibody) kit for serum (Serum-ELISA) were used for determination of the concentration-dependent recovery of MCs in MC-spiked serum. Human serum samples were spiked with varying concentrations of MCs (MC-LR, -YR, -RR, -LA, -LW, -LF and defined MC mixtures) and extracted using two different methods. MC-spiked bovine serum and standard cell culture medium containing 10% FBS served to investigate potential matrix effects. Inter-laboratory comparison was performed allowing identification of potential sources of error. The results suggest that both ELISAs are suitable tools for the analysis of MCs in human blood serum although both also displayed some weaknesses notably the time needed for sample preparation or the overestimation of some specific MC congener concentrations. Based on the ELISA detection ranges, sample concentration and/or MC spiking may be required for detection of low levels of MCs in human blood.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Two ELISA Methods for the Laboratory Diagnosis of Acute Leptospirosis

Background: Leptospirosis is the most common zoonosis widespread in tropical and temperate countries with low social-economic status. We aimed to compare an ELISA kit with an in-house ELISA assay to test the serum samples of the patients who were suspicious of leptospirosis according to their clinical symptoms. Methods: A total of 282 serum samples of patients suspicious of leptospirosis admitt...

متن کامل

Comparison between conventional PCR and PCR - ELISA for detection of Brucella melitensis

Molecular detection techniques are believed to be key tools for both prevention and treatment follow up of brucellosis within live stock and human beings. Consequently rapid, reliable, easy to perform and automated systems for Brucella detection are urgently needed to allow early diagnosis and adequate antibiotic therapy in time. Brucellosis is a worldwide re-emerging zoonosis causing high econ...

متن کامل

The Effect of Different Stabilizers on Stability of Horseradish Peroxidase- Bovine Serum Albumin-Aflatoxin B1, a Conjugated Tracer for Detection of Aflatoxin B1 in Immunoassay-Based Methods

Aflatoxins are a group of fungal toxic metabolites, which are contaminated certain food commodities. ELISA is one of the sensitive methods for detection of aflatoxins. Preparation and stabilizing of a proper conjugated tracer for detection of aflatoxins is probably the main step for designing an ELISA method. In current study, different stabilizers were applied to stabilize a newly prepared con...

متن کامل

Comparison of Immunoblotting and ELISA for Detection of Anti-Ganglioside Antibodies in Children with Guillain-Barre Syndrome

Background: Anti-ganglioside antibody assays are widely used for diagnosis of autoimmune peripheral neuropathies. Objective: This study aimed to determine serum levels of anti-ganglioside antibodies in children with Guillain-Barre syndrome by immunoblotting technique and compare the results with those obtained by ELISA method. Method: In this investigation, 50 children with Guillain-Barre syndr...

متن کامل

Electrochemiluminesence Epidemiologic Detection of Toxoplasma gondii Infection in Pregnant Women With Direct and Indirect Diagnostic Techniques (ELISA Avidity Plus Biochemical Assay)

Background and aims: Toxoplasmosis is a very common disease in the world. Two types of acquiredtoxoplasmosis have been detected. In the chronic toxoplasmosis, the abnormality of tissue functionis little but, in acute toxoplasmosis, function of RES system becomes interrupted. The assessment oftoxoplasma antibody with tissue enzymes in this stage is very important. Furthermore, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Chemico-biological interactions

دوره 223  شماره 

صفحات  -

تاریخ انتشار 2014