Signal and noise transfer in spatiotemporal quantum-based imaging systems.
نویسندگان
چکیده
Fourier-based transfer theory is extended into the temporal domain to describe both spatial and temporal noise processes in quantum-based medical imaging systems. Lag is represented as a temporal scatter in which the release of image quanta is delayed according to a probability density function. Expressions describing transfer of the spatiotemporal Wiener noise power spectrum through quantum gain and scatter processes are derived. Lag introduces noise correlations in the temporal domain in proportion to the correlated noise component only. The effect of lag is therefore dependent on both spatial and temporal physical processes. A simple model of a fluoroscopic system shows that image noise is reduced by a factor that is similar to Wagner's information bandwidth integral, which depends on the temporal modulation transfer function.
منابع مشابه
Optimization of Imaging Parameters in Micro-CT Scanner Based On Signal-To-Noise Ratio for the Analysis of Urinary Stone Composition
Introduction: Micro-CT scanner with a resolution of about 5 micrometers is one of the modalities used to create three-dimensional/two-dimensional images of urinary stones. This study aimed to optimize imaging parameters in micro-computed tomography (CT) scanner based on the signal-to-noise ratio (SNR) of urinary stones for the analysis of stone composition. <stro...
متن کاملEnhancement of Noise Performance in Digital Receivers by Over Sampling the Received Signal
In wireless channel the noise has a zero mean. This channel property can be used in the enhancement of the noise performance in the digital receivers by oversampling the received signal and calculating the decision variable based on the time average of more than one sample of the received signal. The averaging process will reduce the effect of the noise in the decision variable that will approa...
متن کاملREPRINT Title : Lossy cardiac x - ray image compression based on acquisition noiseAuthors :
In lossy medical image compression, the requirements for the preservation of diagnostic integrity cannot be easily formulated in terms of a perceptual model. Especially since, in reality, human visual perception is dependent on numerous factors such as the viewing conditions and psycho-visual factors. Therefore, we investigate the possibility to develop alternative measures for data loss, based...
متن کاملOptimum parameters of nonlinear integrator using design of experiments based on Taguchi method
For many physical systems like vehicles, acceleration can be easily measured for the respective states. However, the outputs are usually affected by stochastic noise disturbance. The mentioned systems are often sensitive to noise and structural uncertainties. Furthermore, it is very difficult to estimate the multiple integrals of the signal, acceleration to velocity and velocity to position. In...
متن کاملShearlet-Based Adaptive Noise Reduction in CT Images
The noise in reconstructed slices of X-ray Computed Tomography (CT) is of unknown distribution, non-stationary, oriented and difficult to distinguish from main structural information. This requires the development of special post-processing methods based on the local statistical evaluation of the noise component. This paper presents an adaptive method of reducing noise in CT images employing th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the Optical Society of America. A, Optics, image science, and vision
دوره 24 12 شماره
صفحات -
تاریخ انتشار 2007