Comparison of Surface Coil and Automatically-tuned, Flexible Interventional Coil Imaging in a Porcine Knee

نویسندگان

  • R. Venook
  • B. Hargreaves
  • S. Conolly
  • G. Gold
  • G. Scott
چکیده

R. Venook, B. Hargreaves, S. Conolly, G. Gold, G. Scott Electrical Engineering, Stanford University, Stanford, CA, United States, Radiology, Stanford University, Stanford, CA, United States Introduction There is a great deal of prior work regarding the advantage of using a surface coil versus a body coil to achieve high local SNR [1,2]. But there is not yet a careful, experimental comparison between surface coils and electronically tuned interventional coils. Here we present results from an in vitro porcine knee study comparing high resolution images from a 3-inch surface coil and a minimally invasive, automatically tuned, 1-inch flexible interventional coil. Early experiments reveal that, even at 1.5T, a closely-fitted birdcage coil will achieve higher SNR for structures beyond 6cm deep than will any size of conventional surface coil [3]. To do better one can place a smaller, invasive probe closer to the region of interest. Under controlled probe shape and loading conditions, such as with endorectal and intravascular imaging, this has worked well [4,5]. However, more general interventional coils require remote operation and a variable shape, which both introduce practical problems with tuning and matching. Our prior work provides analysis of such issues, and circuitry for automatic tuning of a flexible interventional probe [6]. We used this hardware (figure 1) to collect images for comparison against a 3-inch surface coil. Methods To evaluate the performance of our flexible, 1-inch interventional coil, we imaged the patella-femoral cartilage and condylar notch of an in vitro pig knee in a GE Signa 1.5T scanner. In each case, we first placed a 3-inch surface coil over the patella and imaged using standard 3D FIESTA (SSFP) sequences of 6cm and 15cm FOV (30 degree flip, 0.7mm and 1mm slice, 256). After removing the surface coil, we surgically implanted the flexible coil within the interarticular space of the patella-femoral joint. We performed electronic autotuning of the coil after implantation, and imaged using identical scan parameters. Finally, we repeated the whole process after implanting the coil in the posterior condylar notch between the femur and the tibia. We measured the SNR of the complex image data using MATLAB (Mathworks, Inc.). Results The SNR of images with the flexible coil was substantially higher than the SNR of the surface coil images in all cases. Figure 2(a,b) displays similar slices of the same pig knee—with identical scan parameters—from the surgically-implanted coil and from the 3-inch surface coil. The flexible coil exhibits SNR gains by a factor of 3 within the center of the patella-femoral cartilage (9.5 vs. 3.1, +/0.2). The images of the posteriorly located intracondylar notch are in figure 2(c,d). Here, the flexible coil’s SNR remains above 10, while that of the surface coil falls below 2. Conclusion As expected, the smaller coil produces images with superior SNR to those of the 3-inch coil. Comparing it within the best ROI of the 3-inch coil (patella-femoral cartilage) we might predict a factor of 3/2 = 13.5 increase in SNR due to shrinking the coil diameter by a factor of three, and doubling of the effective noise volume (because the smaller coil is surrounded by tissue). However, this presumes that inductively coupled sample noise dominates. Loaded/unloaded Q measurements of our small coil suggest that conductive and dielectric losses are also important. Hence, we find that the factor of 3 increase in SNR is reasonable. The real benefit of using a small, flexible interventional coil for clinical work is that it retains high local SNR for arbitrary depths of target anatomy if well-matched to the preamplifier. With automatic tuning, we can maintain this SNR while allowing the coil to conform to anatomy. We have shown this to be true with our system. For a 7cm target depth, we witness SNR gains near an order of magnitude versus a 3-inch surface coil. This enables resolution increases by a factor of 2-3 without sacrificing either SNR or scan time. Clinically, these gains could make the difference between a minimally-invasive image-based diagnosis, and arthroscopy in cases such as cartilage flaps or transplants. References [1] Hoult, D. et al, JMR 1976, 24: 71-85 [2] Edelstein, W. et al, MRM 1986, 3: 604-618 [3] Hayes, C. et al, Med Phys 1985, 12(5): 604-607 [4] Martin, J. et al, Radiology 1988, 167(1):268-270 [5] Ocali, O. et al, MRM 1997, 37(1): 112-118 [6] Venook, R. et al, Proc. ISMRM 2002: 893 Figure 1: (a) Experimental setup. (b) Automatic tuning electronics. The phase detector relays coil tuning condition to the micro-controller, which automatically adjusts the RF coil tuning with a DC voltage. (a)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Varactor Tuning of Interventional RF Receiver Coils

R. Venook, G. Gold, B. Hu, G. Scott Stanford University, Stanford, CA, United States, Palo Alto Medical Foundation, Palo Alto, CA, United States Synopsis: Small, flexible RF coils are well suited for interventional applications because of their locally-high SNR and deployability. These characteristics also make such coils easily detuned/mismatched, which can hamper imaging performance. This wor...

متن کامل

3-D RF Coil Design Considerations for MRI

High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

Static Coil Design Considerations for the Magnetic Resonance Imaging

One of the main challenges in developing magnetic resonance imaging (MRI) systems is to create a static coil that needs to generate magnetic field density along with the characteristics of optimal homogeneity and magnitude size. To do this, two N42 Block PMs are used and the iron core is designed and optimized in accordance with the dimensions of PM pieces using ANSYS Maxwell software. Then, al...

متن کامل

Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI)

Introduction Signal intensity uniformity in a magnetic resonance (MR) image indicates how well the MR imaging (MRI) system represents an object. One of the major sources of image non-uniformity in high-field MRI scanners is inhomogeneity of radio-frequency coil. The aim of this study was to investigate non-uniformity in head, head and neck, and body coils and compare the obtained results to det...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003