GTEM Cell Experimental Set up for In Vitro Dosimetry
نویسندگان
چکیده
A GTEM cell, suitable for assessing possible biological effects induced on cell samples by electromagnetic fields at the typical frequencies of GSM mobile phones, has been designed and set up. Basic environmental requirements for in-vitro biological experiments, involving a GTEM cell, have been assessed by controlling the electromagnetic field distribution and survival conditions. The GTEM cell has been characterized by Standing Wave Ratio (SWR) and Time Domain Reflectometry (TDR) measurements. The impedance matching at the terminal load section has been optimized by considering different hybridload configurations. Moreover, optimal exposure conditions for the biological sample have been experimentally evaluated by paying special attention to the E-field scenario inside the GTEM cell at 900 MHz and 1800 MHz frequencies. At last, an experimental evaluation of the Specific Absorption Rate (SAR) is reported.
منابع مشابه
Electromagnetic Interference Emitted from Electronic Devices
Measuring the level of electromagnetic interference emitted by electronic devices is an important part of the process of production and development of these devices. Today, these measurements are performed by specialized laboratories that are equipped with an anechoic or semi-anechoic chamber. For manufacturers of electronic devices, it would be beneficial if a Gigahertz Transversal Electromagn...
متن کاملA Gtem Best Practice Guide – Applying Iec 61000-4-20 to the Use of Gtem Cells
The draft standard IEC 61000-4-20 includes the GTEM cell as a measurement facility for emission and immunity tests. A Best Practice Guide is being written, giving guidance how to perform measurements according to this standard, and with acceptable uncertainties. This paper presents some results of the research performed to produce this guide. Frequencies above 1 GHz are increasingly required fo...
متن کاملبررسی صحیح بودن مقدار اشعه داده شده در پرتودرمانی سرطان پستان با ترمولومینسانس دوزیمتری
In vivo dosimetry seems an appropriate method for quality assurance in radiotherapy with CO-60, which can be considered as a routine program in radiotherapy centers. In this study, entrance and exit dose in tangential fields were measured in phantom for 30 breast cancer patients by using TLD in radiotherapy section of Imam Khomeini Hospital. TLD crystals were calibrated against SSDL (Secondary...
متن کاملMeasurements of Antenna Parameters in GTEM Cell
The paper presents the method for measuring parameters (gain, antenna factor, impedance and radiation pattern) of small antennas in GTEM cell, which is a novel method and environment for antenna measurements. In order to investigate the suitability of GTEM cell for this kind of measurement, the measurement results for a biconical dipole, microstrip patch antennas and small loop antenna were com...
متن کاملStandard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...