Closed-loop control of mean arterial blood pressure during surgery with alfentanil: clinical evaluation of a novel model-based predictive controller.

نویسندگان

  • Martin Luginbühl
  • Christian Bieniok
  • Daniel Leibundgut
  • Rolf Wymann
  • Andrea Gentilini
  • Thomas W Schnider
چکیده

BACKGROUND In contrast to hypnosis, there is no surrogate parameter for analgesia in anesthetized patients. Opioids are titrated to suppress blood pressure response to noxious stimulation. The authors evaluated a novel model predictive controller for closed-loop administration of alfentanil using mean arterial blood pressure and predicted plasma alfentanil concentration (Cp Alf) as input parameters. METHODS The authors studied 13 healthy patients scheduled to undergo minor lumbar and cervical spine surgery. After induction with propofol, alfentanil, and mivacurium and tracheal intubation, isoflurane was titrated to maintain the Bispectral Index at 55 (+/- 5), and the alfentanil administration was switched from manual to closed-loop control. The controller adjusted the alfentanil infusion rate to maintain the mean arterial blood pressure near the set-point (70 mmHg) while minimizing the Cp Alf toward the set-point plasma alfentanil concentration (Cp Alfref) (100 ng/ml). RESULTS Two patients were excluded because of loss of arterial pressure signal and protocol violation. The alfentanil infusion was closed-loop controlled for a mean (SD) of 98.9 (1.5)% of presurgery time and 95.5 (4.3)% of surgery time. The mean (SD) end-tidal isoflurane concentrations were 0.78 (0.1) and 0.86 (0.1) vol%, the Cp Alf values were 122 (35) and 181 (58) ng/ml, and the Bispectral Index values were 51 (9) and 52 (4) before surgery and during surgery, respectively. The mean (SD) absolute deviations of mean arterial blood pressure were 7.6 (2.6) and 10.0 (4.2) mmHg (P = 0.262), and the median performance error, median absolute performance error, and wobble were 4.2 (6.2) and 8.8 (9.4)% (P = 0.002), 7.9 (3.8) and 11.8 (6.3)% (P = 0.129), and 14.5 (8.4) and 5.7 (1.2)% (P = 0.002) before surgery and during surgery, respectively. A post hoc simulation showed that the Cp Alfref decreased the predicted Cp Alf compared with mean arterial blood pressure alone. CONCLUSION The authors' controller has a similar set-point precision as previous hypnotic controllers and provides adequate alfentanil dosing during surgery. It may help to standardize opioid dosing in research and may be a further step toward a multiple input-multiple output controller.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Perioperative Closed-loop Control of Analgesia in Humans

We present a new paradigm for intraoperative closed-loop control of analgesia in humans. The infusion rate of the opiate alfentanil is the manipulated variable which is administered intravenously through a Computer Controlled Infusion Pump (CCIP). The two regulated outputs are the patient’s Mean Arterial Pressure (MAP) and the drug concentration in the plasma. Maintaining MAP within acceptable ...

متن کامل

Blood oxygenation during hyperpressure intraperitoneal fluid administration in a rabbit model of severe liver injury: Evaluation of a novel concept for control of pre-hospital liver bleeding

Oxygen is an essential part of the most important metabolic pathways in aerobic organisms. Oxygen delivery is merely dependent on blood, rendering blood loss a devastating event. Traumatic pre-hospital liver bleeding is a major cause of early trauma deaths in human and animals, with no established therapeutic method yet. Increasing intra-abdominal pressure (IAP) has been shown to reduce liver b...

متن کامل

Sedation following cardiac surgery: evaluation of alfentanil and morphine in the presence of a computerized closed loop arterial pressure controller.

Forty patients who had undergone coronary artery graft surgery and who required vasodilator therapy for postoperative hypertension were given infusions of either alfentanil or morphine together with bolus doses of midazolam for sedation and analgesia while ventilation was controlled artificially. Sodium nitroprusside (SNP) was administered to both groups using a computer-controlled closed loop ...

متن کامل

Chaotic dynamic analysis and nonlinear control of blood glucose regulation system in type 1 diabetic patients

In this paper, chaotic dynamic and nonlinear control in a glucose-insulin system in types I diabetic patients and a healthy person have been investigated. Chaotic analysis methods of the blood glucose system include Lyapunov exponent and power spectral density based on the time series derived from the clinical data. Wolf's algorithm is used to calculate the Lyapunov exponent, which positive val...

متن کامل

Constrained Model Predictive Control of Low-power Industrial Gas Turbine

Nowadays, extensive research has been conducted for gas turbine engines control due to growing importance of gas turbine engines for different industries and the need to design a suitable control system for a gas turbine as the heart of the industry. In order to design gas turbine control system, various control variables can be used, but in the meantime, fuel flow inserting into combustion cha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Anesthesiology

دوره 105 3  شماره 

صفحات  -

تاریخ انتشار 2006