Evidence that conflict regarding size of haemodynamic response to interventricular delay optimization of cardiac resynchronization therapy may arise from differences in how atrioventricular delay is kept constant

نویسندگان

  • S.M. Afzal Sohaib
  • Andreas Kyriacou
  • Siana Jones
  • Charlotte H. Manisty
  • Jamil Mayet
  • Prapa Kanagaratnam
  • Nicholas S. Peters
  • Alun D. Hughes
  • Zachary I. Whinnett
  • Darrel P. Francis
چکیده

AIMS Whether adjusting interventricular (VV) delay changes haemodynamic efficacy of cardiac resynchronization therapy (CRT) is controversial, with conflicting results. This study addresses whether the convention for keeping atrioventricular (AV) delay constant during VV optimization might explain these conflicts. METHOD AND RESULTS Twenty-two patients in sinus rhythm with existing CRT underwent VV optimization using non-invasive systolic blood pressure. Interventricular optimization was performed with four methods for keeping the AV delay constant: (i) atrium and left ventricle delay kept constant, (ii) atrium and right ventricle delay kept constant, (iii) time to the first-activated ventricle kept constant, and (iv) time to the second-activated ventricle kept constant. In 11 patients this was performed with AV delay of 120 ms, and in 11 at AV optimum. At AV 120 ms, time to the first ventricular lead (left or right) was the overwhelming determinant of haemodynamics (13.75 mmHg at ±80 ms, P < 0.001) with no significant effect of time to second lead (0.47 mmHg, P = 0.50), P < 0.001 for difference. At AV optimum, time to first ventricular lead again had a larger effect (5.03 mmHg, P < 0.001) than time to second (2.92 mmHg, P = 0.001), P = 0.02 for difference. CONCLUSION Time to first ventricular activation is the overwhelming determinant of circulatory function, regardless of whether this is the left or right ventricular lead. If this is kept constant, the effect of changing time to the second ventricle is small or nil, and is not beneficial. In practice, it may be advisable to leave VV delay at zero. Specifying how AV delay is kept fixed might make future VV delay research more enlightening.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cardiac resynchronization therapy during rest and exercise: comparison of two optimization methods

AIMS Optimal exercise programming of cardiac resynchronization therapy (CRT) devices is unknown. We aimed to: (i) investigate variations in optimal atrioventricular (AV) and interventricular (VV) delays from rest to exercise, assessed by both echocardiography and an automated intracardiac electrogram (IEGM) method; (ii) evaluate the acute haemodynamic impact of CRT optimization performed during...

متن کامل

Atrioventricular and interventricular delay optimization and response quantification in biventricular pacing: arrival of reliable clinical algorithms and research protocols, and how to distinguish them from unreliable counterparts.

In this issue of the journal, Bogaard et al. assess the achievable haemodynamic increment within individuals of optimizing atrioventricular (AV) and interventricular (VV) delays. Biventricular pacing, or cardiac resynchronization therapy (CRT), arguably the greatest advancement in the treatment of heart failure in the last decade, causes immediate increases in haemodynamics and then improvement...

متن کامل

Doppler echocardiographic methods for optimization of the atrioventricular delay during cardiac resynchronization therapy.

Cardiac resynchronization therapy (CRT) is beneficial for a majority of patients with medically refractory heart failure due to severe left ventricular (LV) systolic dysfunction and prolonged interventricular conduction to improve symptoms and LV performance. An optimally programmed atrioventricular delay (AVD) during CRT can be also important to maximize the response in left ventricular functi...

متن کامل

Optimization of cardiac resynchronization guided by Doppler echocardiography: haemodynamic improvement and intraindividual variability with different pacing configurations and atrioventricular delays.

AIMS Cardiac resynchronization therapy (CRT) improves symptoms in heart failure patients with intraventricular conduction delay (IVCD). Different pacing modalities produce variable activation patterns and are likely to result in different haemodynamic changes. The objective of this study was to demonstrate acute haemodynamic changes with different CRT configurations. METHODS AND RESULTS In 26...

متن کامل

Echocardiographic optimization of the atrioventricular and interventricular intervals during cardiac resynchronization.

An optimized atrioventricular (AV) interval can maximize the benefits of cardiac resynchronization therapy (CRT). If programmed poorly, it may curtail beneficial effects of CRT. AV optimization will not convert non-responder to responder, but may convert under-responder to improved status. There are many echocardiographic techniques for AV optimization but there is no universally accepted gold ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015