Use of a flow-injection sample manipulator as an interface between a "high-performance" liquid chromatograph and an atomic absorption spectrophotometer.

نویسندگان

  • B W Renoe
  • C E Shideler
  • J Savory
چکیده

We describe an integrated, molecular-absorbance, atomic absorption instrument for studying metal/ligand binding in clinical samples. For an interface between the "high-performance" liquid chromatograph and the atomic absorption instrument we used a flow-injection sample manipulator, thus allowing both the chromatograph and the atomic absorption detector to operate at their separate optimum conditions. After specimen separation with a gel permeation column, we measured the molecular components of the column eluate by molecular absorbance spectrometry and the atomic components (calcium and magnesium) by flame atomic absorption spectrophotometry. This instrument system is capable of separating and analyzing multiple components within 20 min of injection of the sample on the column. The chromatograms presented demonstrate the utility of the system for investigating metal binding to a variety of ligands in clinical samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dispersive Liquid-Liquid Microextraction Based on Solidification of Floating Organic Drop Combined with Flame Atomic Absorption Spectrometry for Preconcentration and Determination of Thallium(III) in Water Samples

Dispersive Liquid-Liquid MicroExtraction technique based on Solidification of a Floating Organic drop (DLLME-SFO) combined with flame atomic absorption spectrometry was developed for determination of thallium in water sample. An appropriate mixture of acetone and 1-undecanol was rapidly injected into an aqueous sample containing TlCl4- which forms an ion pair with bril...

متن کامل

A sequential injection cold-vapor atomic absorption method for the determination of total mercury.

A sequential injection (SI) method for the determination of mercury via cold vapor atomic absorption spectrophotometry is presented. The method differs from flow injection (FI) cold vapor methods for the determination of mercury because of the simplicity of the system required for the method: one pump, one valve, a gas-liquid separator, and an atomic absorption spectrophotometer equipped with a...

متن کامل

Design and operation of an autosampler controlled flow-injection preconcentration system for lead determination by flame atomic absorption spectrometry

Flow-injection manifolds are described which allow the preconcentration of lead for flame atomic absorption determinations, using columns contained within the sample loop of an injection valve. An interface was designed which allowed the valves and pump in the system to be controlled by an autosampler which enabled precise timing of preconcentration and elution steps. The effects of sample flow...

متن کامل

Preconcentration and determination of palladium water samples by ionic liquid - dispersive liquid liquid microextraction combined with flame atomic absorption spectrometry

A simple, rapid and efficient dispersive liquid–liquid microextraction by use of ionic liquid (IL-DLLME)method, followed by flame atomic absorption spectrometry (FAAS) was developed for the preconcentrationand determination of palladium in water samples. In this method, an appropriate mixture of acetone and octylmethyl imidazolium hexafluorophosphate was injected rapidly into the aqueous sample...

متن کامل

Dispersive liquid–liquid microextraction based on solidification of floating organic drop combined with flame atomic absorption spectrometry for determination trace amount of cobalt in water samples

An efficient, rapid, simple, and highly selective dispersive liquid–liquid microextraction basedon solidification of floating organic drop (DLLME-SFOD), combined with flame atomicabsorption spectrometry was developed for preconcentration and determination of trace amountsof cobalt in water samples. In this method, an appropriate mixture of acetone and1-undecanol was injected rapidly into the aq...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 27 9  شماره 

صفحات  -

تاریخ انتشار 1981