Dynamic-locking-screw (DLS)–leads to less secondary screw perforations in proximal humerus fractures

نویسندگان

  • Thomas Freude
  • Steffen Schroeter
  • Michael Plecko
  • Christian Bahrs
  • Frank Martetschlaeger
  • Tobias M Kraus
  • Ulrich Stoeckle
  • Stefan Doebele
چکیده

BACKGROUND Loss of reduction and screw perforation causes high failure rates in the treatment of proximal humerus fractures. The purpose of the present study was to evaluate the early postoperative complications using modern Dynamic Locking Screws (DLS 3.7) for plating of proximal humerus fractures. METHODS Between 03/2009 and 12/2010, 64 patients with acute proximal humerus fractures were treated by angular stable plate fixation using DLSs in a limited multi-centre study. Follow-up examinations were performed three, six, twelve and twenty-four weeks postoperatively and any complications were carefully collected. RESULTS 56 of 64 patients were examined at the six-month follow-up. Complications were observed in 12 patients (22%). In five cases (9%), a perforation of the DLS 3.7 occurred. CONCLUSIONS Despite the use of modern DLS 3.7, the early complications after plating of proximal humerus fractures remain high. The potential advantage of the DLS 3.7 regarding secondary screw perforation has to be confirmed by future randomized controlled trials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

Assessment of Screw Length of Proximal Humerus Internal Locking System (PHILOS) Plate for Proximal Humeral Fractures Using Three-Dimensional Computed Tomography Scan

BACKGROUND Screw perforation and varus collapse are common complications of treatment with a PHILOS (proximal humerus internal locking system) plate for proximal humerus fractures, which are associated with improper screw length selection and lack of medial column support. The purposes of this study were: (1) to measure the proper length of periarticular screws of the PHILOS plate in the humera...

متن کامل

Locking plate fixation for proximal humerus fractures.

Locking plates are increasingly used to surgically treat proximal humerus fractures. Knowledge of the bone quality of the proximal humerus is important. Studies have shown the medial and dorsal aspects of the proximal humeral head to have the highest bone strength, and this should be exploited by fixation techniques, particularly in elderly patients with osteoporosis. The goals of surgery for p...

متن کامل

[Measurement of screw length through drilling technique in osteosynthesis of the proximal humerus fractures].

OBJECTIVES This study aims to investigate the efficacy of screw length measurement through drilling technique on the reduction of intraarticular screw penetration and fluoroscopy time in osteosynthesis of proximal humerus fractures. PATIENTS AND METHODS Between January 2008 and June 2012, 98 patients (34 males, 64 females; mean age 64.4 years; range 35 to 81 years) who underwent osteosynthesi...

متن کامل

Fluoroscopic Technique for Open Reduction and Internal Fixation of Proximal Humeral Fracture Using the Proximal Humeral Locking Plate: Proposal of “Plate” and “Screw” Views

Proximal humeral fractures are common injuries with increasing incidence, particularly in the aging population. Nondisplaced or minimally displaced fractures can be treated conservatively whereas surgical fixation is usually indicated in the cases of displaced fractures. Various surgical options have been used for treatment of these fractures. Good outcomes have been reported with use of the Pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014