High-accuracy wavefront control for retinal imaging with Adaptive-Influence-Matrix Adaptive Optics.

نویسندگان

  • Weiyao Zou
  • Stephen A Burns
چکیده

We present an iterative technique for improving adaptive optics (AO) wavefront correction for retinal imaging, called the Adaptive-Influence-Matrix (AIM) method. This method is based on the fact that the deflection-to-voltage relation of common deformable mirrors used in AO are nonlinear, and the fact that in general the wavefront errors of the eye can be considered to be composed of a static, non-zero wavefront error (such as the defocus and astigmatism), and a time-varying wavefront error. The aberrated wavefront is first corrected with a generic influence matrix, providing a mirror compensation figure for the static wavefront error. Then a new influence matrix that is more accurate for the specific static wavefront error is calibrated based on the mirror compensation figure. Experimental results show that with the AIM method the AO wavefront correction accuracy can be improved significantly in comparison to the generic AO correction. The AIM method is most useful in AO modalities where there are large static contributions to the wavefront aberrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptive optics with pupil tracking for high resolution retinal imaging

Adaptive optics, when integrated into retinal imaging systems, compensates for rapidly changing ocular aberrations in real time and results in improved high resolution images that reveal the photoreceptor mosaic. Imaging the retina at high resolution has numerous potential medical applications, and yet for the development of commercial products that can be used in the clinic, the complexity and...

متن کامل

Digital Holographic Adaptive Optics for Retinal Imaging

A new adaptive optics retinal imaging system is presented that is based on the principles of digital holography and dispenses with the wavefront sensor and wavefront corrective element of the conventional adaptive optics system. OCIS codes: 090.1995; 110.1080; 170.4470

متن کامل

Wavefront sensorless adaptive optics ophthalmoscopy in the human eye

Wavefront sensor noise and fidelity place a fundamental limit on achievable image quality in current adaptive optics ophthalmoscopes. Additionally, the wavefront sensor 'beacon' can interfere with visual experiments. We demonstrate real-time (25 Hz), wavefront sensorless adaptive optics imaging in the living human eye with image quality rivaling that of wavefront sensor based control in the sam...

متن کامل

Adaptive Optics Optical Coherence Tomography for in Vivo Retinal Imaging

Optical coherence tomography (OCT) is a non-invasive micrometer-resolution volumetric imaging modality that has been employed in diverse applications. In this thesis, we first describe a GPU accelerated program to perform FDOCT data processing and real time 3D volumetric rendering. The real time visualization of volumetric images provided by the GPU acceleration was essential to the rest of the...

متن کامل

Optimization of the open-loop liquid crystal adaptive optics retinal imaging system.

An open-loop adaptive optics (AO) system for retinal imaging was constructed using a liquid crystal spatial light modulator (LC-SLM) as the wavefront compensator. Due to the dispersion of the LC-SLM, there was only one illumination source for both aberration detection and retinal imaging in this system. To increase the field of view (FOV) for retinal imaging, a modified mechanical shutter was i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics express

دوره 17 22  شماره 

صفحات  -

تاریخ انتشار 2009