North-Holland, Amsterdam RESIDUAL GAS BEAM PROFILE MONITOR

نویسنده

  • John KRIDER
چکیده

The design and performance of a beam profile monitor which presents no material to the beam is described. The detector, which has a 75 mm active width, operates from residual gas in the beam vacuum system . It provides 1 mm rms spatial resolution and 1 ms time resolution in a 1 ALA beam at 10-7 Torr . Using a microprocessor based scanning ADC, a sequence of ten profiles can be acquired in as little as 100 ms . The monitor could be applied in other stored or extracted beams where the amount of material seen by the beam must be minimized .

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Luminescence Beam Profile Monitor for Intense Proton and Heavy Ion Beams

A new luminescence beam profile monitor is realized in the polarized hydrogen gas jet target at the Relativistic Heavy Ion Collider (RHIC) facility. In addition to the spin polarization of the proton beam being routinely measured by the hydrogen gas jet, the luminescence produced by beam-hydrogen excitation leads to a strong Balmer series lines emission. A selected hydrogen Balmer line is spect...

متن کامل

Beam Transverse Profile Monitors for Ifmif-eveda

In the framework of the IFMIF-EVEDA project, a high deuteron beam intensity (125 mA 9 MeV) prototype accelerator will be built and tested at Rokkasho (Japan). CEA-Saclay group and CIEMAT-Madrid (Spain) are responsible for the beam instrumentation from the ion source to the beam dump. One of the most challenging diagnostic is the Beam Transverse Profile Monitor. Two kinds of monitor are investig...

متن کامل

Gas Scintillation Beam Profile Monitor at Cosy Jülich *

The interaction of ion beams with the surrounding residual gas leads to photon emission by the excited residual gas atoms and molecules. These photons in the visible spectrum range can be used to monitor the transverse beam profile. We therefore use a multichannel photomultiplier (PMT) together with an optical imaging system. Measurements at COSY synchrotron of the Forschungszentrum Jülich are ...

متن کامل

Characterizing Supersonic Gas Jet-based Beam Profile Monitors

The next generation of high power, high intensity accelerators requires non-invasive diagnostics, particularly beam profile monitors. Residual gas-based diagnostics such as ionization beam profile or beam induced fluorescence monitors have been used to replace commonly used scintillating screens. At the Cockcroft Institute an alternative technique using a supersonic gas jet, shaped into a 45 cu...

متن کامل

BIF Profile Monitor for the UNILAC - Tests and DAQ Upgrade

The non-intercepting Beam Induced Fluorescence (BIF) monitor for transverse beam profile measurements was successfully tested for different ion species and energies from 5 to 750 MeV/u at the GSI accelerators [1]. Starting from its first implementation [2] we systematically investigated technical aspects such as the proper choice of optics and gain factors, as well as physical aspects like the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002