Noncontact optical measurement of lens capsule thickness in human, monkey, and rabbit postmortem eyes.
نویسندگان
چکیده
PURPOSE To measure interspecies thickness differences in the central anterior and posterior capsules of postmortem crystalline lenses, by a technique that maintains the anatomic integrity of the lens. METHODS Central capsule thickness was measured with a custom-built, noncontact optical system, using a focus detection technique. Anterior and posterior lens capsule thickness measurements were performed on 22 human, 29 monkey, and 34 New Zealand White rabbit intact postmortem lenses in situ. Eyes were prepared for optical measurements by bonding a PMMA ring to the sclera in the region of the ciliary body after the conjunctiva, adipose, and muscle tissues were removed. The posterior pole was removed by making a circumferential incision through the sclera approximately 7 mm posterior to the limbus. Excess vitreous was removed to expose the posterior capsule surface, and the eye assembly was placed on a Teflon slide. The cornea and iris were sectioned to expose the anterior capsule surface. After the experiments, the lenses were excised, placed in 10% buffered formalin, and prepared for histology. Lens capsule thickness was measured from the histologic slides and compared to the optical RESULTS results. Central anterior lens capsule thickness was 8.2 +/- 5.5 (human), 7.5 +/- 4.4 (monkey), and 10.7 +/- 4.2 (rabbit) microm optically and 12.4 +/- 2.5 (human), 10.7 +/- 3.7 (monkey), and 10.4 +/- 2.0 (rabbit) microm histologically. Central posterior capsule thickness was 6.3 +/- 2.2 (human), 5.9 +/- 1.7 (monkey), and 7.8 +/- 2.3 (rabbit) microm optically and 4.1 +/- 1.5 (human), 3.5 +/- 1.6 (monkey), and 4.7 +/- 2.5 (rabbit) microm histologically. CONCLUSIONS The central anterior and posterior lens capsule thicknesses do not appear to vary considerably among human, rabbit, and monkey eyes. There were significant differences between optical in situ measurements and histology, which indicates that histologic preparation may affect lens capsule thickness.
منابع مشابه
Ultrasonographic Measurement of the Anterior and Posterior Lens Capsules of the Eyes and its Comparison with a Field Study in Normal Rabbit
Objective- To find normal value of thickness of the lens capsules in domesticated rabbits by ultrasonography. Design- experimental in vivo study and clinical trial. Animals- Twelve matured and immature domesticated rabbit. Procedures- The eyes of 12 non anaesthetized domesticated rabbits were sonograophed using a linear 6-12 MHz high frequency transducer. The thickness of anterior and posterior...
متن کاملUse of three-dimensional ultrasonography of the eye and measurement of optical long axis in dog
This study was conducted to determine the use of three-dimensional ultrasonography (3DU) in ocular imaging of the dog and measuring of its optical axis. 12 healthy mixed-breed dogs including 6 males and 6 females were studied. 3DU of the eyes were done using a 5–12 MHz linear trapezoid transducer. 3DU of the eyes were evaluated and the normal optical long axis through a line between the cornea ...
متن کاملThree Dimensional Ultrasonography of the Eye and Measurement of Optical Nerve Sheet Diameter in Dog
Objective- To determine the possibility of three-dimensional ultrasonography (3DUS) and measurement of optical nerve sheet by this method. Design- Descriptive study. Animals- 10 mixed normal dogs (5males, 5 females), age 1-1.5 year, and weighting 15±5 kg Procedure- 3D ultrasounds of the eyes were evaluated and the normal optical nerves in 3DUS images were measured using Volouson 730 pro....
متن کاملOptomechanical response of human and monkey lenses in a lens stretcher.
PURPOSE To quantify the forces necessary to change the shape and optical power of human and monkey lenses. METHODS Cynomolgus monkey (n = 48; age: 3.8-11 years), rhesus monkey (n = 35; age: 0.7-17 years) and human (n = 20, age 8-70 years) eyes obtained postmortem, including the lens, capsule, zonules, ciliary body, and sclera were mounted in an optomechanical lens-stretching system. Starting ...
متن کاملLens thickness assessment: anterior segment optical coherence tomography versus A-scan ultrasonography.
AIM To assess lens thickness measurements with anterior segment-optical coherence tomography (AS-OCT) in comparison with A-scan ultrasonography (A-scan US). METHODS There were 218 adult subjects (218 eyes) aged 59.2±9.2y enrolled in this prospective cross-sectional study. Forty-three eyes had open angles and 175 eyes had narrow angles. Routine ophthalmic exam was performed and nuclear opacity...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 46 5 شماره
صفحات -
تاریخ انتشار 2005