BACKGROUND/AIMS Povidone-iodine (PVP -I) is applied for microbial decontamination of human eyes donated for transplantation. Concentrations and immersion times vary greatly. The effectiveness and toxicity of PVP-I were assessed for different decontamination protocols. METHODS Human donor eyes and corneas were immersed in different concentrations (5-100 mg/ml) of PVP-I for different times (2-30 minutes). The penetration of iodine into the corneal tissue was assessed by x ray microanalysis. Microbial contamination was determined by taking cultures of the limbal areas and storage solutions and by incubation of the corneoscleral buttons in antibiotic-free culture medium. Cytotoxicity of PVP-I for corneal fibroblasts in culture was assessed using the MTT assay. RESULTS Depending on concentration and immersion time iodine was found to penetrate into the epithelium, Bowman's layer, and stroma in amounts equivalent to 2-40 mg/ml PVP-I. The MTT assay demonstrated that 2.5 mg/ml PVP-I caused total damage to fibroblasts in vitro. Rinsing eyes with tap water and subsequent immersion in PVP-I reduced the rate of contamination from 82 out of 106 to 69 out of 106 and 37 out of 106, respectively. Antibiotics in the storage medium further reduced contamination from about 40% to 3%. Microbial contamination was not reduced by increasing the concentration and immersion times beyond 5 mg/ml PVP-I for 2 minutes. CONCLUSION Immersion of human donor eyes in 5 mg/ml PVP-I solution for 2 minutes significantly reduces microbial contamination of donor corneas without relevant penetration of iodine into the corneal layers. Higher PVP-I concentrations and longer immersion times do not further reduce contamination, whereas the amount of iodine penetrating the corneal layers is elevated above the level cytotoxic for corneal fibroblasts. In view of this, concentrations above 5 mg/ml of PVP-I and immersion periods over 2 minutes are not recommended for reduction of the contamination rate of donor eyes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decontamination of Gutta-percha Cones with Different Chemical Agents

The purpose of this study was to evaluate the effectiveness of various chemical disinfectants in decontamination of gutta-percha (GP) cones contaminated with Bacillus subtilis spores. Sodium hypochlorite solution (4%), glutaraldehyde solution (2%), povidone-iodine solution (5%), and savlon solutions were compared for effectiveness in sterilizing gutta-percha cones contaminated with Bacillus sub...

متن کامل

EFFECT OF INTRAOCULAR POVIDONE-IODINE SOLUTION IN PREVENTION OF BACTERIAL ENDOPHTHALMITIS IN A RABBIT MODEL

In order to determine the effects of intraocular 0.05% povidone-iodine preparation in the prevention of bacterial endophthalmitis in a rabbit model, 28 albino rabbits were randomly assigned to 4 equal groups. A concentration of 5x 108 organisms (0.03 mL) in logarithmic growth phase of S. epidermidis, S. aureus, Proteus mirabilis and Pseudomonas aeruginosa, were injected separately in the a...

متن کامل

Effect of surgical site skin preparation with povidone-iodine 7.5% and 10% with chlorhexidine and povidone-iodine 10% on microbial count

Background and Aim: Preparing the skin for surgery with antiseptics is a standard measure to reduce surgical site infection. This study aimed to evaluate the effect of skin preparation at the surgical site with povidone-iodine 7.5% and povidone-iodine 10% antiseptics with chlorhexidine and povidone-iodine 10% on the microbial count. Methods: This clinical trial study was performed on 80 patient...

متن کامل

Preventing infection from reusable medical equipment: a systematic review

BACKGROUND In 2000, the World Health Organization (WHO) had eight sets of conflicting recommendations for decontaminating medical equipment. We conducted a systematic review of observational studies to assist WHO in reconciling the various guidelines. This paper summarises the methods developed and illustrates the results for three procedures--alcohol, bleach and povidone iodine. METHODS We d...

متن کامل

Are dropped osteoarticular bone fragments safely reimplantable in vivo?

BACKGROUND There are limited data detailing the appropriate management of nondisposable autologous osteoarticular fragments that have been contaminated by the operating room floor. The goal of the present study was to perform a comprehensive, three-phase investigation to establish an appropriate intraoperative algorithm for the management of the acutely contaminated, but nondisposable, autologo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 83 9  شماره 

صفحات  -

تاریخ انتشار 1999