A comparison of polyethylene wear rates between cemented and cementless cups. A prospective, randomised trial.
نویسندگان
چکیده
We selected randomly a consecutive series of 162 patients requiring hip replacement to receive either a cementless, hemispherical, modular, titanium acetabular cup or a cemented, all-polyethylene cup. These replacements were performed by two surgeons in four general hospitals. The same surgical technique was used and a 26 mm metal-head femoral component was used in every case. After exclusions, 115 hips were studied for differences in rates of wear and osteolysis. The mean clinical follow-up was eight years and the mean radiological follow-up, 6.5 years. The cementless cups wore at a mean rate of 0.15 mm per year and the cemented cups at 0.07 mm per year. This difference was significant (p < 0.0001). Our findings in this mid-term study suggest that cementless cups wear more than cemented cups.
منابع مشابه
In vivo measurement of polyethylene wear in cementless total hip arthroplasty.
PURPOSE OF THE STUDY Recent years have seen an increase in cementless total hip endoprosthesis (THP) implantations. Easy radiological measurement of wear in cups coated with X-ray dense material, such as metal or ceramics, is not applicable. An alternative technique has thus been developed to radiographically measure wear on cementless spherical implants. MATERIAL AND METHODS The authors pres...
متن کاملComparison of polyethylene wear with femoral heads of 22 mm and 32 mm. A prospective, randomised study.
In this prospective, randomised study, we have compared the wear rate of cemented, acetabular polyethylene cups articulating with either a 22 mm or a 32 mm cobalt-chromium head. We evaluated 89 patients who had a total of 484 radiographs. The mean follow-up period was 71.4 months (SD 29.1). All the radiographs were digitised and electronically measured. The linear wear rate was significantly hi...
متن کاملCementless fixation in total knee arthroplasty: down the boulevard of broken dreams - affirms.
There has been a recent increase in interest for non-cemented fixation in total knee arthroplasty (TKA), however the superiority of cement fixation is an ongoing debate. Whereas the results based on Level III and IV evidence show similar survivorship rates between the two types of fixation, Level I and II evidence strongly support cemented fixation. United Kingdom, Australia, Sweden,...
متن کاملPolyethylene wear in total hip arthroplasty.
Polyethylene wear increasingly has been blamed for osteolysis and granuloma formation after total joint arthroplasty. The authors evaluated the wear difference between bearing surfaces of stainless steel, cobalt chrome, and titanium alloy. They also compared cemented all-polyethylene molded cups with cemented metal-backed molded acetabular cups. These were compared with molded and machined poly...
متن کاملResults of 3,668 primary total hip replacements
BACKGROUND AND PURPOSE In a previous study based on the Finnish Arthroplasty Register, the survival of cementless stems was better than that of cemented stems in younger patients. However, the survival of cementless cups was poor due to osteolysis. In the present study, we analyzed population-based survival rates of the cemented and cementless total hip replacements in patients under the age of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 87 3 شماره
صفحات -
تاریخ انتشار 2004