Accuracy of hysteroscopy in the diagnosis of endometrial cancer and hyperplasia: a systematic quantitative review.
نویسندگان
چکیده
CONTEXT Hysteroscopy (direct endoscopic visualization of the endometrial cavity) is used extensively in the evaluation of common gynecologic problems, such as menorrhagia and postmenopausal bleeding. However, there is a continuing debate about the value of this technology in the diagnosis of serious endometrial disease. OBJECTIVE To determine the accuracy of hysteroscopy in diagnosing endometrial cancer and hyperplasia in women with abnormal uterine bleeding. DATA SOURCES Relevant articles were identified through searches of the Cochrane Library, MEDLINE, and EMBASE (1984-2001), manual searches of bibliographies of known primary and review articles, and contact with manufacturers. STUDY SELECTION Studies were selected blindly, independently, and in duplicate if accuracy of hysteroscopy was estimated in women with abnormal uterine bleeding, using histopathologic findings as a reference standard. Our search identified 3486 articles; 208 of these were deemed to be potentially eligible and were retrieved for detailed data extraction. Sixty-five primary studies were analyzed, including 26 346 women. DATA EXTRACTION Data were abstracted on characteristics and quality from each study. Results for diagnostic accuracy were extracted to form 2 x 2 contingency tables separately for endometrial cancer and endometrial disease (cancer, hyperplasia, or both). Pooled likelihood ratios (LRs) were used as summary accuracy measures. DATA SYNTHESIS The pretest probability of endometrial cancer was 3.9% (95% confidence interval [CI], 3.7%-4.2%). A positive hysteroscopy result (pooled LR, 60.9; 95% CI, 51.2-72.5) increased the probability of cancer to 71.8% (95% CI, 67.0%-76.6%), whereas a negative hysteroscopy result (pooled LR, 0.15; 95% CI, 0.13-0.18) reduced the probability of cancer to 0.6% (95% CI, 0.5%-0.8%). There was statistical heterogeneity in pooling of LRs, but an explanation for this could not be found in spectrum composition and study quality. The overall accuracy for the diagnosis of endometrial disease was modest compared with that of cancer, and the results were heterogeneous. The accuracy tended to be higher among postmenopausal women and in the outpatient setting. CONCLUSION The diagnostic accuracy of hysteroscopy is high for endometrial cancer, but only moderate for endometrial disease (cancer or hyperplasia).
منابع مشابه
Accuracy of hysteroscopy in the diagnosis of endometrial cancer and hyperplasia: a systematic quantitative review
Searching MEDLINE and EMBASE were searched from January 1984 to December 2001, employing the MeSH and textwords for the term 'hysteroscopy' combined with the MeSH term 'diagnosis'. Studies reported in any language were considered. In addition, the Cochrane Library was searched, the reference lists of all known reviews and primary studies were examined, and the manufacturers of hysteroscopes wer...
متن کاملAccuracy of hysteroscopy in the diagnosis of endometrial cancer and hyperplasia: a systematic quantitative review
Searching MEDLINE and EMBASE were searched from January 1984 to December 2001, employing the MeSH and textwords for the term 'hysteroscopy' combined with the MeSH term 'diagnosis'. Studies reported in any language were considered. In addition, the Cochrane Library was searched, the reference lists of all known reviews and primary studies were examined, and the manufacturers of hysteroscopes wer...
متن کاملDiagnostic accuracy of sonohysterography compared to endometrial biopsy in pre-menopausal women with abnormal uterine bleeding
Background: AUB is a common cause of women’s referring to gynecologists. Although hysteroscopy is known as the gold standard technique for diagnosing the cause of AUB, sonohysterography is less invasive, and it is performed by general gynecologists. The purpose of this study was to evaluate the diagnostic performance of sonohysterography compared to the results of the endometrial biopsy, guid...
متن کاملDiagnostic Accuracy of Transvaginal Sonography in Infertile Patients with Endometrial Polyps
Background To evaluate the diagnostic accuracy of transvaginal sonography (TVS) in infertile patients and compare its results with hysteroscopy as the gold standard. MaterialsAndMethods A total of 679 infertile women who underwent both TVS and diagnostic hysteroscopy were retrospectively investigated. TVS was performed in the mid-follicular phase (days 5-8) of their cycles. Sensitivity specific...
متن کاملAssessment of transvaginal ultrasonography accuracy in the diagnosis of uterine pathologies in women with abnormal uterine bleeding
Abstract Background: The most common causes of abnormal uterine bleeding in women of reproductive age are uterine structural abnormalities. There are several modalities for the examination of abnormal uterine bleeding, including transvaginal ultrasound and hysteroscopy. In this study, we aimed to investigate the diagnostic accuracy of hysteroscopy versus transvaginal ultrasound in the diagnosis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JAMA
دوره 288 13 شماره
صفحات -
تاریخ انتشار 2002