Ion Migration in the Process of Water Freezing under Alternating Electric Field and Its Impact on Insulator Flashover

نویسندگان

  • Xingliang Jiang
  • Quanlin Wang
  • Zhijing Zhang
  • Jianlin Hu
  • Qin Hu
  • Chengzhi Zhu
چکیده

Ice flashover threatens the security and reliability of power transmission. However, the ice flashover mechanism of insulators remains poorly understood. This study analyses water droplet freezing and ion distribution in ice layer under alternating electric field. It also investigates ion migration during icing process of insulator string under alternating electric field and its effects on insulator flashover. Results showed that the average freezing time of water droplets was related to electric field strength. The extent of ion migration during freezing decreased with increasing electric field strength. The maximal melting water conductivity of the ice layer and icicle of the insulator formed under energized condition was higher than the corresponding freezing water conductivity but lower than that under non-energized condition. Furthermore, the hanging location of each insulator significantly affected the melting water conductivity of the ice layer. The surface conductivity of the ice layer increased because of the conductive ion migration in freezing water during freezing, which was an important factor that decreased the flashover voltage of the ice-covered insulator. The existence of alternating electric field would impact the extent of ion migration. This study may serve as a reference for updating prediction flashover model of ice-covered insulators during the melting period.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Disc Insulator Type and Corona Ring on Electric Field and Voltage Distribution over 230-kV Insulator String by Numerical Method

Insulator strings with several material and profiles are very common in overhead transmission lines. However, the electric field and voltage distribution of insulator string is uneven which may easily lead to corona, insulators’ surface deterioration and even flashover. So the calculation of the electric field and voltage distribution along them is a very important factor in the operation time....

متن کامل

Natural Contamination and Surface Flashover on Silicone Rubber Surface under Haze–Fog Environment

Anti-pollution flashover of insulator is important for power systems. In recent years, haze-fog weather occurs frequently, which makes discharge occurs easily on the insulator surface and accelerates insulation aging of insulator. In order to study the influence of haze-fog on the surface discharge of room temperature vulcanized silicone rubber, an artificial haze-fog lab was established. Based...

متن کامل

Effects of Statically Electric Fields on Freezing Parameters and Microstructures of Button Mushrooms (Agaricus bisporus)

Background and Objectives: Freezing under statically electric fields is one of the novel freezing methods to improve the quality of frozen products by controlling the nucleation process. The objective of this study was to investigate effects of freezing under electrostatic fields on the freezing parameters and microstructures of frozen button mushrooms. Materials and Methods: Mushroom samples w...

متن کامل

Impact of Pollution Location on Time and Frequency Characteristics of Leakage Current of Porcelain Insulator String under Different Humidity and Contamination Severity

One of the important factors influencing outdoor insulators performance is pollution phenomenon. The pollution, especially during humidity condition, reduces superficial resistance of insulator and lead to a flow of Leakage Currents (LC) on the insulator surface, which may result in total flashover. The LC characteristics are affected by parameters such as nature and severity of pollution. Loca...

متن کامل

Analysis of Flashover Voltages of Disc Type Insulator under Artificial Pollution Condition (TECHNICAL NOTE)

Through this paper work we have analyzed the effect of different contaminants on the flashover by creating artificial pollution condition, considering the natural condition where more than one salt as contaminant deposits on the surface of insulator at a time, under the wet condition that cause flow of highly leakage current, that leads to flashover. We choses the mixture of different salts, so...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017