Few electron response and spurious background of linear focused photomultipliers

نویسندگان

  • R. Bollmann
  • W. Scobel
  • K. Woller
چکیده

The compact, linear focused ten-stage photomultipliers Hamamatsu R 1450 and R 1355 have been studied with light pulses generating small numbers (1V,< 25) of photoelectrons . Good amplitude resolution for single photoelectrons as well as for small signals in general was obtained by considerably increasing the supply voltage Ut of the first dynode . The time resolution is dominated by the statistical variation of Ne. The importance of background from microdischarges and Cherenkov radiation is discussed .

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Vacuum problems of miniaturization of vacuum electronic components: a new generation of compact photomultipliers

Recently, a new generation of compact photomultipliers exhibiting high sensitivity, fast time response, extremely low background and extended dynamic range has been introduced. The electron multiplication is enabled by a high-gain and extremely low-background, closed-end, channel electron multiplier serving also as a body of the new mini electron tube. By preventing ultra-fine leaks by the intr...

متن کامل

Spurious Response Suppression in Waveguide Filters using E-Shaped Chiral Resonators

In this paper, chiral E-shaped resonators are used in a waveguide. Direction of EM wave and position of resonators for effective excitation is studied and various resonances of E-shaped resonators are determined. As a consequence an analytical equivalent circuit model is proposed. Finally, an array of these resonators is used to realize a wide reject band. The resulted band stop filter performa...

متن کامل

Verification of dose rate and energy dependence of MAGICA polymer gel dosimeter with electron beams

Background: The purpose of this study was to evaluate the dependency of MAGICA polymer gel dosimeter response (R2) on different electron energies as well as on different mean dose rate for a standard clinically used linear accelerator. Materials and Methods: The sensitivity of the dosimeter was represented by the slope of calibration curve in the linear region measured for each modalit...

متن کامل

Studies on electron beam induced DNA damage and repair kinetics in lymphocytes by alkaline comet assay

Background: Exposure to ionizing radiation is known to induce oxidative stress followed by damage to critical biomolecules like lipids, proteins and DNA through radiolysis of cellular water. Since radiation has been widely used as an important tool in therapy of cancer, the detailed investigation regarding the DNA damage and repair kinetics would help to predict the radiation sensitivity of cel...

متن کامل

Calibration of photomultipliers gain used in the J-PET detector

Photomultipliers are commonly used in commercial PET scanner as devices which convert light produced in scintillator by gamma quanta from positron-electron annihilation into electrical signal. For proper analysis of obtained electrical signal, a photomultiplier gain curve must be known, since gain can be significantly different even between photomultipliers of the same model. In this article we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002