Finite Element Modelling of NiTi Shape Memory Alloy Abutment for an Osseointegration Trans-femoral Implant
نویسنده
چکیده
Traditionally, prosthetic limb is interconnected to the residual limb via a “socket”. As the body weight upon the prosthesis is transferred through soft tissue to human skeleton, the muscles and skin could be traumatized. To overcome the problem, an osseointegration trans-femoral implant technique has been used to attach prosthetic limb to human skeleton directly. However, due to the malfunction of the prosthetic limb and accidentally loss balance of the prosthetic limb user, a significant impact load could over load the implanted bone. To protect the bone, a shape memory alloy (SMA) abutment was developed. Finite element (FE) method was used to investigate the mechanical performance of NiTi SMA abutments under both static and impact load conditions. In this study, a non-linear FE model was applied to simulate the large deformation of the abutment. The simulation in terms of the maximum stress involved and plastic deformation was used a) for safety and reliability assessment of the abutment, and b) as input for the further study of interfacial stress between femur and implant. A comparison of FE modelling was also made between NiTi SMA and other materials used in the clinical trials. The results reveal that NiTi SMA abutment can release much more impact load and reduce the over stress in the bone significantly.
منابع مشابه
The axisymmetric computational study of a femoral component to analysis the effect of titanium alloy and diameter variation.
This work presents a numerical approach in order to predict the influence of implant material stiffness in a femoral component design when submitted in compression. The implant success depends on the transferred load to the neighboring bone. The finite element method can be used to analysis the stress and strain distribution in the femoral component allowing to improve the implant selection. Fo...
متن کاملFinite Element Simulation of NiTi Umbrella-Shaped Implant Used on Femoral Head under Different Loadings
In this study, an umbrella-shaped device that is used for osteonecrosis treatment is simulated. The femoral head is subjected to various complex loadings as a result of a person's daily movements. Implant devices used in the body are made of shape memory alloy materials because of their remarkable resistance to wear and corrosion, good biocompatibility, and variable mechanical properties. Since...
متن کاملEvaluating the impact of length and thread pitch on the stress distribution in dental implants and surrounding bone using finite element method
longevity of osseointegrated implants are intensely influenced by biomechanical factors. Control of these factors prevents mechanical complications, which include fracture of screws, components, or materials veneering the framework. In this study, the impact of length and threads pitch of dental implants on the stress distribution and maximum Von Mises stress in implant-abutment complex and ja...
متن کاملMultiscale Modeling of Polycrystalline NiTi Shape Memory Alloy under Various Plastic Deformation Conditions by Coupling Microstructure Evolution and Macroscopic Mechanical Response
Numerical modeling of microstructure evolution in various regions during uniaxial compression and canning compression of NiTi shape memory alloy (SMA) are studied through combined macroscopic and microscopic finite element simulation in order to investigate plastic deformation of NiTi SMA at 400 °C. In this approach, the macroscale material behavior is modeled with a relatively coarse finite el...
متن کاملNumerical evaluation of bone remodelling associated with trans-femoral osseointegration implant--A 68 month follow-up study.
Osseointegrated trans-femoral implant is a relatively new orthopaedic anchoring method for connecting a stump with a prosthesis. Through a follow-up study of a patient over six years, significant bone remodelling has been observed. Finite element (FE) simulations were carried out to investigate the relationship between the bone remodelling and the strain re-distribution around the trans-femoral...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -