Concentrations of plasma immunoglobulins in the dog as determined by laser nephelometry. Comparison with radial immunodiffusion and enzyme-linked immunosorbent assay.

نویسندگان

  • P J Ginel
  • J M Margarito
  • R Lucena
  • J M Molleda
چکیده

Concentrations of immunoglobulins were determined by laser nephelometry and, for comparison, by single radial immunodiffusion assay and a sandwich enzyme-linked immunosorbent assay (ELISA) in plasma samples of normal dogs. Correlation between methods was high, although the mean IgM concentrations determined by laser nephelometry were significantly higher than those determined by the single radial immunodiffusion assay or ELISA. In contrast, the mean IgA concentrations were significantly lower than those determined by ELISA. Laser nephelometry was the most reproducible method. The between-assay coefficient of variation was 4.12% for IgG, 6.98% for IgM and 6.35% for IgA. Laser nephelometry and ELISA showed similar accuracies, and both were more accurate than single radial immunodiffusion. Finally, laser nephelometry was much more sensitive than single radial immunodiffusion, but less sensitive than the ELISA method. In conclusion, results of the three methods were in general comparable. The higher range of linearity precision and accuracy of laser nephelometry, and the availability of automated nephelometers make this the method of choice for quantifying canine plasma immunoglobulins.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of immunoglobulin determinations in pathological sera by radial immunodiffusion and laser nephelometry.

Immunoglobulins G, A, and M were measured by radial immunodiffusion and by laser nephelometry in sera from 33 patients and in a preparation of purified colostral IgA. In general the results agreed for the two methods, with some exceptions attributed to the physicochemical characteristics of the immunoglobulins assayed: low-molecular-weight (monomeric) IgM gives falsely high values and IgA prote...

متن کامل

Comparison of radial immunodiffusion and laser nephelometry for quantitating some serum proteins.

After quantitating immunoglobulins G, A, and M and complement C3c and C4 in serum by using a laser nephelometer coupled with a data processor, I compared these results with values obtained by an early-readout radial immunodiffusion method. Day-to-day precision was better for nephelometry than for radial immunodiffusion for all proteins analyzed. The average coefficient of variation was 6.0% for...

متن کامل

DEVELOPMENT OF A SIMPLE AND SENSITIVE ENZYME- LINKED IMMUNOSORBENT ASSAY (ELISA) FOR CLINICAL MEASUREMENT OF TESTOSTERONE USING PENICILLINASE AS LABEL

An enzyme-linked immunosorbent assay using a homologous combination of antiserum raised against testosterone-3-0-carboxymethyloxime-bovine serum albumin (T-3-0-CMO-BSA ) and penicillinase-labelled T-3-0-CMO was developed. This assay was utilized to measure testosterone in serum samples of male and female subjects. The sensitivity of the assay is 50pg/well and the antibody developed crossrea...

متن کامل

Designing an enzyme-linked immunosorbent assay for detection of anti-penicillin antibodies levels in various species of animals in Khuzestan province, Iran

The penicillin allergy is being increasingly recognized as a significant public health problem. Immunological responses to penicillin and other beta-lactam antibiotics are classified as immediate and non-immediate responses. This research aimed to develop an enzyme-linked immunosorbent assay (ELISA) for the detection of the reactive antibody value against penicillin in various species of animals...

متن کامل

Determination of immunoglobulin A in saliva by immunobead enzyme-linked immunosorbent assay: comparison with single radial immunodiffusion.

For the quantitative measurement of immunoglobulin A in human saliva, an immunobead enzyme-linked immunosorbent assay was investigated in detail. The method proved to be fast and sensitive, and it gave reproducible results. There was a strong correlation with results obtained by a single radial immunodiffusion method. The immunobead method gave 1.8 times higher values than the single radial imm...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of clinical chemistry and clinical biochemistry : journal of the Forum of European Clinical Chemistry Societies

دوره 35 3  شماره 

صفحات  -

تاریخ انتشار 1997