Quantitative Analysis of Staphylococcal Enterotoxins A and B in Food Matrices Using Ultra High-Performance Liquid Chromatography Tandem Mass Spectrometry (UPLC-MS/MS)
نویسندگان
چکیده
A method that uses mass spectrometry (MS) for identification and quantification of protein toxins, staphylococcal enterotoxins A and B (SEA and SEB), in milk and shrimp is described. The analysis was performed using a tryptic peptide, from each of the toxins, as the target analyte together with the corresponding (13)C-labeled synthetic internal standard peptide. The performance of the method was evaluated by analyzing spiked samples in the quantification range 2.5-30 ng/g (R² = 0.92-0.99). The limit of quantification (LOQ) in milk and the limit of detection (LOD) in shrimp was 2.5 ng/g, for both SEA and SEB toxins. The in-house reproducibility (RSD) was 8%-30% and 5%-41% at different concentrations for milk and shrimp, respectively. The method was compared to the ELISA method, used at the EU-RL (France), for milk samples spiked with SEA at low levels, in the quantification range of 2.5 to 5 ng/g. The comparison showed good coherence for the two methods: 2.9 (MS)/1.8 (ELISA) and 3.6 (MS)/3.8 (ELISA) ng/g. The major advantage of the developed method is that it allows direct confirmation of the molecular identity and quantitative analysis of SEA and SEB at low nanogram levels using a label and antibody free approach. Therefore, this method is an important step in the development of alternatives to the immune-assay tests currently used for staphylococcal enterotoxin analysis.
منابع مشابه
Novel approach to fast determination of multiple pesticide residues using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS).
A rapid, high-throughput method employing ultra-performance liquid chromatography with tandem quadrupole mass spectrometry (UPLC-MS/MS) was developed and optimized for simultaneous quantification and confirmation of 64 pesticide residues and their toxic metabolites in fruit extracts prepared by a buffered QuEChERS procedure. The total time required for UPLC-MS/MS analysis was 8 min plus 2 min f...
متن کاملAnalysis of Staphylococcus enterotoxin B using differential isotopic tags and liquid chromatography quadrupole ion trap mass spectrometry.
Staphylococcus aureus produces enterotoxins, which are causative agents of foodborne intoxications. Enterotoxins are single-chain polypeptides and have a molecular weight of about 26-28 kDa. The consumption of food contaminated with Staphylococcus aureus enterotoxins results in the onset of acute gastroenteritis within 2-6 h. The objective of this study was the development of a new method for t...
متن کاملUltra-performance liquid chromatography-tandem mass spectrometry: a novel challenge in multiresidue pesticide analysis in food.
Potential of ultra-performance liquid chromatography (UPLC) separation strategy coupled with tandem (in space) mass spectrometric detection (MS/MS) in multiresidue pesticide analysis was critically assessed. Performance parameters such as number of theoretical plates, height of theoretical plate, peak symmetry and peak capacity were measured/calculated on the basis of data generated by analysis...
متن کاملQuantification of bovine β-casein allergen in baked foodstuffs based on ultra-performance liquid chromatography with tandem mass spectrometry
The quantification of allergens in food including baked food matrices is of great interest. The aim of the present study was to describe a non-immunologic method to quantify bovine β-casein using ultra-performance liquid chromatography tandem triple quadrupole mass spectrometry (UPLC-TQ-MS/MS) in multiple reaction monitoring (MRM) mode. Eight of 10 theoretical peptides from β-casein after trypt...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -