Drop-to-drop variation in the cellular components of fingerprick blood: implications for point-of-care diagnostic development.

نویسندگان

  • Meaghan M Bond
  • Rebecca R Richards-Kortum
چکیده

OBJECTIVES Blood obtained via fingerprick is commonly used in point-of-care assays, but few studies have assessed variability in parameters obtained from successive drops of fingerprick blood, which may cause problems for clinical decision making and for assessing accuracy of point-of-care tests. METHODS We used a hematology analyzer to analyze the hemoglobin concentration, total WBC count, three-part WBC differential, and platelet count in six successive drops of blood collected from one fingerprick from each of 11 donors, and we used a hemoglobinometer to measure the hemoglobin concentration of 10 drops of fingerprick blood from each of 7 donors. RESULTS The average percent coefficient of variation (CV) for successive drops of fingerprick blood was higher by up to 3.4 times for hemoglobin, 5.7 times for WBC count, 3 times for lymphocyte count, 7.7 times for granulocyte count, and 4 times for platelets than in venous controls measured using a hematology analyzer. The average percent CV for fingerprick blood was up to 5 times higher for hemoglobin than venous blood measured using a point-of-care hemoglobinometer. Fluctuations in blood parameters with increasing volume of fingerprick blood are within instrument variability for volumes equal to or greater than 60 to 100 μL. CONCLUSIONS These data suggest caution when using measurements from a single drop of fingerprick blood.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic study on an immunochromatographic rapid test for schistosomiasis: comparison between use on serum and on blood spot from fingerprick

BACKGROUND An immunochromatographic rapid test (ICT; Schistosoma ICT IgG-IgM, LDBIO Diagnostics) demonstrated high sensitivity (96%) in the diagnosis of Schistosoma mansoni and S. haematobium. To date, the test has been validated for use on serum only, but in the absence of lab equipment, blood drop from fingerprick could be a useful option. This method is acquiring more interest because of the...

متن کامل

Effects of fasting on Blood pressure in normotensive males

Muslims all over the world fast in the holy month of Ramadan. Fasting means abstinence from drinking any liquids, eating, smoking and taking anything parenterally.  It is intermittent in nature from the start of dawn to end at dusk. Fasting has various physiological effects on different biological parameters of the human body. Previous studies that look at effect of Ramadan fasting on blood pre...

متن کامل

The Influence of the Pipe’s Material and the Mass Flow Rate on the Pressure Drop and Velocity Variation During Pneumatic Conveying of Wheat Using Computational Fluid Dynamics

According to flexibility of pneumatic conveying systems with respect to other types of transmission systems, this system has wide application in industry and agriculture processes. One important application of this system is in the loading and unloading tankers and powdery bulk materials such as trucks carrying cement, plaster and sand. Conveying efficiency is associated with pressure, which in...

متن کامل

The Influence of the Pipe’s Material and the Mass Flow Rate on the Pressure Drop and Velocity Variation During Pneumatic Conveying of Wheat Using Computational Fluid Dynamics

According to flexibility of pneumatic conveying systems with respect to other types of transmission systems, this system has wide application in industry and agriculture processes. One important application of this system is in the loading and unloading tankers and powdery bulk materials such as trucks carrying cement, plaster and sand. Conveying efficiency is associated with pressure, which in...

متن کامل

The Study of Corresponding Effects of anionic surfactant concentration and solute on Drop Size in a Mixer-Settler Extractor and Propose an Empirical Model

Drop size distribution in a mixer-settler is an essential design parameter, as obtaining drop size distribution will result in optimum performance of equipment. In this paper for obtaining drop size, several experiments have been performed with a single stage horizontal mixer-settler. A video technique has been used in order to measure the drop size in the mixer-settler with the help of a digit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • American journal of clinical pathology

دوره 144 6  شماره 

صفحات  -

تاریخ انتشار 2015