چکیده

AIM Many studies are available in the literature on posterior spinal instrumentation, though the use of a rod and a plate is still controversial in the literature. In this study, a finite element analysis of the strength and superiority of modular rigid plate and rod systems, which are used in the lower lumbar region, in comparison with each other was used. MATERIAL AND METHODS A Ti6Al4V (Grade 5) titanium biocompatible alloy anterior plate was used for the lumbar spine fixation device, and a finite element analysis was conducted on the human lumbar spine model. In this study, an intact spine, a rigid system fixed with a rod, and modular plate systems were evaluated at flexion, extension, lateral bending, and axial rotation. RESULTS They did not show statistically significant superiority over one another in terms of limitations in movement during the range of motion exercises and rigidity. CONCLUSION The posterior rigid stabilization system and novel stabilization system do not have a significant superiority over one another. Equivalent results in the limitation of movement and rigidity allow for the use of these systems for short-segment posterior spinal instrumentation with the same indications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite Element Analysis of a New Pedicle Screw-Plate System for Minimally Invasive Transforaminal Lumbar Interbody Fusion

PURPOSE Minimally invasive transforaminal lumbar interbody fusion (MI-TLIF) is increasingly popular for the surgical treatment of degenerative lumbar disc diseases. The constructs intended for segmental stability are varied in MI-TLIF. We adopted finite element (FE) analysis to compare the stability after different construct fixations using interbody cage with posterior pedicle screw-rod or ped...

متن کامل

Estimation of spinal loads using a detailed finite element model of the L4-L5 lumbar segment derived by medical imaging kinematics; a feasibility study

Introduction: Low back pain is the most prevalent orthopedic disorder and the first main cause of poor working functionality in developed as wells as many developing countries. In Absence of noninvasive in vivo measurement approaches, biomechanical models are used to estimate mechanical loads on human joints during physical activities. To estimate joint loads via musculoskelet...

متن کامل

Comparison between the effects of Harrington Rod and multisegmented instrumentations in sagittal plane correction of idiopathic scoliosis

 Abstract Objective: To present the changes in projected thoracic hypokyphosis and the behavior of lumbar lordosis within and below the fusion and to compare these changes between the Harrington rod (HR) and posterior multisegmented hook instrumentation. Methods: 178 patients with idiopathic scoliosis, who had undergone posterior spinal fusion with Harrington technique (106 patients) or multise...

متن کامل

Comparison of the Load-sharing Characteristics between Pedicle-based Composite and Rigid Rod Devices

1. Introduction Adjacent segment degeneration (ASD) has been reported as the one of late serious complication after spinal fusion surgery [1-3]. Presumably, the immediate rigidity produced by instrumentation causes more stress leading to accelerated degeneration at adjacent levels [2]. Many previous studies have been corroborated a trend toward earlier development of ASD with instrumentation as...

متن کامل

Biomechanical Stabilization of the Multi-level Corpectomy Construct Using Anterior and Posterior Instrumentation – a Finite Element Model Study

Long segment decompression and strut reconstruction with either an anterior or posterior instrumentation have been shown to promote arthrodesis and minimize bone graft related problems. Numerous surgical techniques to supplement the stability of the multi-level construct have been well documented in the literature using the anterior screw-plate system or posterior screw-plate/rod system. These ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Turkish neurosurgery

دوره 27 4  شماره 

صفحات  -

تاریخ انتشار 2017