CT and MRI Techniques for Imaging Around Orthopedic Hardware.

نویسندگان

  • Thuy Duong Do
  • Reto Sutter
  • Stephan Skornitzke
  • Marc-André Weber
چکیده

Orthopedic hardware impairs image quality in cross-sectional imaging. With an increasing number of orthopedic implants in an aging population, the need to mitigate metal artifacts in computed tomography and magnetic resonance imaging is becoming increasingly relevant. This review provides an overview of the major artifacts in CT and MRI and state-of-the-art solutions to improve image quality. All steps of image acquisition from device selection, scan preparations and parameters to image post-processing influence the magnitude of metal artifacts. Technological advances like dual-energy CT with the possibility of virtual monochromatic imaging (VMI) and new materials offer opportunities to further reduce artifacts in CT and MRI. Dedicated metal artifact reduction sequences contain algorithms to reduce artifacts and improve imaging of surrounding tissue and are essential tools in orthopedic imaging to detect postoperative complications in early stages. KEY POINTS   · Tissues around orthopaedic hardware can still be well visualised despite metal artifacts.. · Artefact reduction in CT: acquisition parameters, iterative reconstruction, Dual-energy CT and VMI.. · Artefact reduction in MRI: choice of device, sequences, acquisition parameters and MARS. CITATION FORMAT · Do TD, Sutter R, Skornitzke S et al. CT and MRI Techniques for Imaging Around Orthopedic Hardware. Fortschr Röntgenstr 2018; 190: 31 - 41.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bimodal magnetic resonance imaging-computed tomography nanoprobes: A Review

Bimodal imaging combines two imaging modalities in order to benefit from their advantages and compensate the limitations of each modality. This technique could accurately detect diseases for diagnostic purposes. Nanoparticles simultaneously offer diagnostic data via various imaging modalities owing to their unique properties. Moreover, bimodal nanoprobes could be incorporated into theranostic s...

متن کامل

Artifacts of Titanium, Zirconium, and Binary Titanium-Zirconium Abutments in Compute Tomography, Cone Beam Computed Tomography, and Magnetic Resonance Imaging

Aim: The aim of this in vitro study was to evaluate imaging artifacts induced by Titanium, Zirconium, Titanium-Zirconium abutments in CT, MRI and CBCT imaging modalities.Methods: A 4×8mm titanium fixture was inserted in a dry human mandible. Titanium, Zirconium and Titanium–Zirconium abutments measuring 10.5 mm in height are located on the fixture, one by one. Each abutment was scan...

متن کامل

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

Medical imaging modalities: Prevention of unnecessary orders and non-optimized radiation exposure

Magnetic resonance imaging (MRI) uses a constant magnetic field and radio waves, a non-invasive method for examining tissues, organs and the skeletal system. Advantages and disadvantages of MRI are not fully understood; however, it has been commonly used in the diagnosis of skeleton and bone diseases (such as disk and spinal disorders, joint disorders (arthritis), bone tumours and tissues...

متن کامل

An Evaluation of Digital Imaging Studies in an Outpatient Orthopedic Setting

Background: Distribution of radiographic images in the outpatient setting on compact discs-recordable (CD-R) iscommonplace. Opening, manipulating and interpreting these can be challenging. This study evaluated the availabilityand ease of use of CD-R to evaluate digital images in an outpatient orthopedic setting.Methods: 118 CD-R containing diagnostic studies were evaluated by ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin

دوره 190 1  شماره 

صفحات  -

تاریخ انتشار 2018