Quantitative assessment of MRI lesion load in multiple sclerosis. A comparison of conventional spin-echo with fast fluid-attenuated inversion recovery.
نویسندگان
چکیده
In this study, we compared a fast fluid-attenuated inversion recovery (fast-FLAIR) sequence to conventional spin-echo (CSE) in the evaluation of brain MRI lesion loads of seven patients with clinically definite multiple sclerosis. Interleaved CSE (3000/20, 5 mm contiguous axial slices) and fast-FLAIR (9000/150/2200, 5 mm contiguous axial slices) sequences were performed on a 1.0 T machine. Lesions were counted consensually by two observers and then segmented independently by two other observers using a local thresholding technique, with subsequent manual editing in the case of poorly defined lesions. Four hundred and two lesions were detected in at least one of the two sequences: 128 were seen only on fast-FLAIR, 17 only on CSE. Forty-one lesions were larger on fast-FLAIR, while no lesion was considered larger on CSE. The numbers of periventricular (P = 0.05), cortical/subcortical (P = 0.02) and discrete (P = 0.05) lesions detected using fast-FLAIR were higher than those detected using CSE. The median lesion load was 7185 mm3 on CSE and 8418 mm3 on the fast-FLAIR, the average being 18% (range = 11.6-29%) higher on the fast-FLAIR images. Lesion contrast ratio was higher for lesions on the fast-FLAIR than on the CSE sequence (P < 0.0001). The percentages of poorly defined lesions which needed manual editing after the local thresholding technique was applied and the total time needed for the measurements were lower (P < 0.001) when fast-FLAIR images were used compared with CSE. This resulted in a reduced inter-rater coefficient of variation in measuring lesion volumes. Our data indicate that fast-FLAIR sequences are more sensitive than CSE in detecting multiple sclerosis lesion burden and that fast-FLAIR is a promising technique for natural history studies and clinical trials in multiple sclerosis.
منابع مشابه
MRI lesion volume measurement in multiple sclerosis and its correlation with disability: a comparison of fast fluid attenuated inversion recovery (fFLAIR) and spin echo sequences.
OBJECTIVES To assess whether multiple sclerosis lesion volume measurements derived using the fast fluid attenuated inversion recovery (fFLAIR) sequence show better reproducibility or correlation with disability than those derived using the conventional spin echo (CSE) sequence. METHODS Part I: twenty five patients with multiple sclerosis were scanned with CSE, fast spin echo (FSE), and fFLAIR...
متن کاملFast spin-echo and fast fluid-attenuated inversion-recovery versus conventional spin-echo sequences for MR quantification of multiple sclerosis lesions.
PURPOSE To compare fast spin-echo (FSE) and fast fluid-attenuated inversion recovery (FLAIR) sequences with conventional spin-echo (CSE) MR imaging in the quantification of the number and volume of multiple sclerosis lesions. METHODS In 30 patients with relapsing-remitting multiple sclerosis, we calculated the total number and volume of lesions detected with each of the three sequences using ...
متن کاملSpinal cord lesions in patients with multiple sclerosis: comparison of MR pulse sequences.
PURPOSE To compare T2-weighted conventional spin-echo (CSE), fast spin-echo (FSE), shorttau inversion recovery (STIR) FSE, and fluid-attenuated inversion recovery (FLAIR) FSE sequences in the assessment of cervical multiple sclerosis plaques. METHODS Twenty patients with clinically confirmed multiple sclerosis and signs of cervical cord involvement were examined on a 1.5-T MR system. Sagittal...
متن کاملThe low sensitivity of fluid-attenuated inversion-recovery MR in the detection of multiple sclerosis of the spinal cord.
PURPOSE To confirm the expected superiority of fluid-attenuated inversion-recovery (FLAIR) over conventional fast spin-echo MR imaging in the detection of multiple sclerosis (MS) of the spinal cord. METHODS Fifteen subjects with known MS involving the spinal cord and brain were studied prospectively. The entire cord was imaged with a phased-array coil on a 1.5-T MR system. Sagittal T1-weighte...
متن کاملComparison of MR pulse sequences in the detection of multiple sclerosis lesions.
PURPOSE To compare the sensitivity of conventional spin-echo, fast spin-echo, fast fluid-attenuated inversion recovery (FLAIR), and turbo gradient spin-echo MR sequences in the detection of multiple sclerosis lesions. METHODS Conventional spin-echo, fast spin-echo, fast FLAIR, and turbo gradient spin-echo sequences were performed on a 1.0-T MR imager in seven patients with clinically definite...