Application of a repeat-measure biomarker measurement error model to 2 validation studies: examination of the effect of within-person variation in biomarker measurements.
نویسندگان
چکیده
Repeat-biomarker measurement error models accounting for systematic correlated within-person error can be used to estimate the correlation coefficient (ρ) and deattenuation factor (λ), used in measurement error correction. These models account for correlated errors in the food frequency questionnaire (FFQ) and the 24-hour diet recall and random within-person variation in the biomarkers. Failure to account for within-person variation in biomarkers can exaggerate correlated errors between FFQs and 24-hour diet recalls. For 2 validation studies, ρ and λ were calculated for total energy and protein density. In the Automated Multiple-Pass Method Validation Study (n=471), doubly labeled water (DLW) and urinary nitrogen (UN) were measured twice in 52 adults approximately 16 months apart (2002-2003), yielding intraclass correlation coefficients of 0.43 for energy (DLW) and 0.54 for protein density (UN/DLW). The deattenuated correlation coefficient for protein density was 0.51 for correlation between the FFQ and the 24-hour diet recall and 0.49 for correlation between the FFQ and the biomarker. Use of repeat-biomarker measurement error models resulted in a ρ of 0.42. These models were similarly applied to the Observing Protein and Energy Nutrition Study (1999-2000). In conclusion, within-person variation in biomarkers can be substantial, and to adequately assess the impact of correlated subject-specific error, this variation should be assessed in validation studies of FFQs.
منابع مشابه
Practice of Epidemiology Application of a Repeat-Measure Biomarker Measurement Error Model to 2 Validation Studies: Examination of the Effect of Within-Person Variation in Biomarker Measurements
Repeat-biomarker measurement error models accounting for systematic correlated within-person error can be used to estimate the correlation coefficient (q) and deattenuation factor (k), used in measurement error correction. These models account for correlated errors in the food frequency questionnaire (FFQ) and the 24-hour diet recall and random within-person variation in the biomarkers. Failure...
متن کاملRe: "Application of a repeat-measure biomarker measurement error model to 2 validation studies: examination of the effect of within-person variation in biomarker measurements".
The paper by Preis et al. (1) contains potentially misleading statements concerning the impact of within-person biomarker variation on the Observing Protein and Energy Nutrition (OPEN) Study results. The major theme of the paper is estimation of deattenuation factors and correlations between intakes reported on a food frequency questionnaire or 24-hour diet recall and true usual intake. A secon...
متن کاملInvited Commentary: OPEN Questions
The papers by Subar et al. (1) and Kipnis et al. (2) in this issue of the Journal provide a unique set of data and a useful contribution to nutritional epidemiology. The Observing Protein and Energy Nutrition (OPEN) Study they report on was based on a reasonable sample of participants, had a remarkably high completion rate, and is the largest known study to use doubly labeled water as the stand...
متن کاملBiomarker efficacy in multiple sclerosis diagnosis and treatment
The goal in studies concerning biomarkers in autoimmune diseases is finding a marker which fluctuates in correlation with the disease’s severity and settles within normal borders after effective treatment. This marker would later be used as an efficient tool in diagnosis and analysis of medicine clout. It seems the most cogent biomarkers are those measurable in serum or plasma. MS is a neurolog...
متن کاملSimultaneous Monitoring of Multivariate Process Mean and Variability in the Presence of Measurement Error with Linearly Increasing Variance under Additive Covariate Model (RESEARCH NOTE)
In recent years, some researches have been done on simultaneous monitoring of multivariate process mean vector and covariance matrix. However, the effect of measurement error, which exists in many practical applications, on the performance of these control charts is not well studied. In this paper, the effect of measurement error with linearly increasing variance on the performance of ELR contr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of epidemiology
دوره 173 6 شماره
صفحات -
تاریخ انتشار 2011