Superior fixation of pegged trabecular metal over screw-fixed pegged porous titanium fiber mesh

نویسندگان

  • Maiken Stilling
  • Frank Madsen
  • Anders Odgaard
  • Lone Rømer
  • Niels Trolle Andersen
  • Ole Rahbek
  • Kjeld Søballe
چکیده

BACKGROUND AND PURPOSE Lasting stability of cementless implants depends on osseointegration into the implant surface, and long-term implant fixation can be predicted using radiostereometric analysis (RSA) with short-term follow-up. We hypothesized that there would be improved fixation of high-porosity trabecular metal (TM) tibial components compared to low-porosity titanium pegged porous fiber-metal (Ti) polyethylene metal backings. METHODS In a prospective, parallel-group, randomized unblinded clinical trial, we compared cementless tibial components in patients aged 70 years and younger with osteoarthritis. The pre-study sample size calculation was 22 patients per group. 25 TM tibial components were fixed press-fit by 2 hexagonal pegs (TM group) and 25 Ti tibial components were fixed press-fit and by 4 supplemental screws (Ti group). Stereo radiographs for evaluation of absolute component migration (primary effect size) and single-direction absolute component migration (secondary effect size) were obtained within the first postoperative week and at 6 weeks, 6 months, 1 year, and 2 years. American Knee Society score was used for clinical assessment preoperatively, and at 1 and 2 years. RESULTS There were no intraoperative complications, and no postoperative infections or revisions. All patients had improved function and regained full extension. All tibial components migrated initially. Most migration of the TM components (n = 24) occurred within the first 3 months after surgery whereas migration of the Ti components (n = 22) appeared to stabilize first after 1 year. The TM components migrated less than the Ti components at 1 year (p = 0.01) and 2 years (p = 0.004). INTERPRETATION We conclude that the mechanical fixation of TM tibial components is superior to that of screw-fixed Ti tibial components. We expect long-term implant survival to be better with the TM tibial component.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty

BACKGROUND Trabecular metal has shown promising results in experimental studies of bone ingrowth. Several clinical studies support these results. However, until now, no randomized clinical radiostereometric analysis (RSA) studies have been published. In this randomized RSA trial, we compared a new acetabular cup with a surface made of tantalum trabecular metal and a cup with a titanium fiber-me...

متن کامل

Radiographic comparison of pegged and keeled glenoid components using modern cementing techniques: a prospective randomized study.

BACKGROUND Modern cementing techniques have improved glenoid fixation, reduced glenoid lucency seen with keeled components, and may eliminate differences attributable to glenoid design. The purpose of this study was to determine the effect of glenoid design on immediate and follow-up radiographic lucency of pegged and keeled glenoid components, using modern cementing techniques. MATERIAL AND ...

متن کامل

The Effect of Trabecular Metal Porous Surface on Gap Healing and Bone Ingrowth Fixation in a Canine Total Hip Model

Introduction An exciting approach to reducing aseptic loosening of cementless implants is the stimulation and acceleration of bone ingrowth into the porous coatings of the implants. Improved fixation of components is an important factor for long term success of total hip and total knee replacement. While one method of stimulating bone formation utilizes biological agents such as BMP-2 or OP-1. ...

متن کامل

Finite Element Analysis Stress Distribution Acetabular Cup Biomaterial FINITE ELEMENT ANALYSIS OF PERI-ACETABULAR STRESS OF CEMENTED, METAL-BACKED, AND POROUS TANTALUM BACKED ACETABULAR COMPONENTS

Introduction: In contemporary THA there are two broad approaches to acetabular cup design and materials. One is an all-polyethylene design with polymethylmethacrylate (PMMA) cement. PMMA possesses a modulus of elasticity of about 2 GPa, which is between that of trabecular and subchondral bone. The second more popular approach, especially for active, younger patients, is the porous metal-backed ...

متن کامل

The radiographic evaluation of keeled and pegged glenoid component insertion.

BACKGROUND Radiolucent lines about the glenoid component of a total shoulder replacement are a common finding, even on initial postoperative radiographs. The achievement of complete osseous support of the component has been shown to decrease micromotion. We evaluated the ability of a group of experienced shoulder surgeons to achieve complete cementing and support in a series of patients managed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 82  شماره 

صفحات  -

تاریخ انتشار 2011