Effects of insertion conditions on tissue strain and vascular damage during neuroprosthetic device insertion.

نویسندگان

  • C S Bjornsson
  • S J Oh
  • Y A Al-Kofahi
  • Y J Lim
  • K L Smith
  • J N Turner
  • S De
  • B Roysam
  • W Shain
  • S J Kim
چکیده

Long-term integration of neuroprosthetic devices is challenged by reactive responses that compromise the brain-device interface. The contribution of physical insertion parameters to immediate damage is not well described. We have developed an ex vivo preparation to capture real-time images of tissue deformation during device insertion using thick tissue slices from rat brains prepared with fluorescently labeled vasculature. Qualitative and quantitative assessments of damage were made for insertions using devices with different tip shapes inserted at different speeds. Direct damage to the vasculature included severing, rupturing and dragging, and was often observed several hundred micrometers from the insertion site. Slower insertions generally resulted in more vascular damage. Cortical surface features greatly affected insertion success; insertions attempted through pial blood vessels resulted in severe tissue compression. Automated image analysis techniques were developed to quantify tissue deformation and calculate mean effective strain. Quantitative measures demonstrated that, within the range of experimental conditions studied, faster insertion of sharp devices resulted in lower mean effective strain. Variability within each insertion condition indicates that multiple biological factors may influence insertion success. Multiple biological factors may contribute to tissue distortion, thus a wide variability was observed among insertions made under the same conditions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Rotational Motion in Robotic Needle Insertion

Background: Robotic needle insertion in biological tissues has been known as one the most applicable procedures in sampling, robotic injection and different medical therapies and operations.Objective: In this paper, we would like to investigate the effects of angular velocity in soft tissue insertion procedure by considering force-displacement diagram. Non-homogenous camel liver can be exploite...

متن کامل

P-170: Zinc and Copper Serum Level Alterations after An Intra Uterine Device Insertion

Background: Intra uterine devices (IUDs) are among the most commonly used contraception methods around the world. The most common form of IUDs used in Iran, is IUD Copper T-380A. As recently there is great emphasis on the role of blood zinc levels on general health conditions, this study was performed to assess the effects of IUD T-380-A insertion on zinc and also copper serum levels. Materials...

متن کامل

Comparing the Effect of Aromatherapy with Salvia officinalis and Topical Lidocaine Gel on Pain Intensity During Insertion of Vascular Catheters in Hemodialysis Patients

  Background and purpose: Hemodialysis is a common treatment for end-stage renal failure, and cannulation causes considerable pain. Topical lidocaine gel and aromatherapy as a complementary medicine are used to relieve the pain. Aromatherapy is associated with fewer side effects than medication, so, the present study was conducted to compare the effect of aromatherapy with Salvia officinalis a...

متن کامل

Analgesia and anesthesia during IUD insertion: local anesthetics

Background: Intrauterine Device (IUD) is an effective and long term method of contraception that can be used without continued effort by the user to prevent pregnancy perfectly. Pain during IUD insertion is one of the obstacles to properly using the device. Thus, using different methods of analgesia and anesthesia to alleviate this pain has been studied by many researchers. This review article ...

متن کامل

The Effects of Grasp Conditions on Maximal Acceptable Combined Forces (pushing and pinch forces) for Manual Insertion of Snap Fasteners

The objective of this study was to determine the effects of grasp conditions (types of grasp, grasp width, glove and types of coupling) on maximal pushing force (MPF) and required pinch force (RPF) during snap fit assembly. The results indicated that the type of grasp, the type of coupling and wearing gloves have significant (p

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of neural engineering

دوره 3 3  شماره 

صفحات  -

تاریخ انتشار 2006