Measurement of tissue optical properties during mechanical compression using swept source optical coherence tomography

نویسنده

  • Yajing Liu
چکیده

Laser-based photo-thermal therapies can provide minimally-invasive treatment of cancers. Their effectiveness is limited by light penetration depth in tissue due to its highly scattering properties. The highly disordered refractive index distribution in tissue leads to multiple-scattering of incident light. It has been hypothesized that mechanical compression has a great potential to enhance the capabilities of laser therapy by inducing localized water transport, decreasing the refractive index mismatch, and decreasing the scattering coefficient of tissue. To better understand this process, we investigated the refractive index change of ex-vivo dog skin during mechanical compression using a swept-source optical coherence tomography (OCT) device built in our lab. The Lorentz-Lorenz rule of mixtures was applied to evaluate the water and protein weight fraction of tissue simultaneously. Results show that the refractive index of skin increased from 1.38 to 1.52 during compression and water content decreased about 60%-70% when the skin sample was compressed by 70%. In addition, we conducted compression experiments on human finger, palm, back of hand, and front of forearm in vivo. OCT images of these skin sites before and after compression by 1 minute were compared. Optical thickness of epidermis and light penetration depth in the dermis were measured. The extended Huygens-Fresnel model was applied to measure the scattering coefficient μs of skin specimens. μs of skin was measured to be about 10-17 mm before compression and decreased 60%-80% after compression, which increases the averaged light intensity by 2-7 dB and almost doubles light penetration depth in dermis. It is quite significant in laser therapies especially for treating epithelia cancers which originate at 1-2 mm beneath the tissue surface. In the OCT imaging of skin dehydration experiment, we conclude that dehydration is an important mechanism of mechanical clearing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo estimation of elastic wave parameters using phase-stabilized swept source optical coherence elastography.

We report a highly sensitive method based on phase-stabilized swept source optical coherence elastography (PhS-SSOCE) to measure elastic wave propagation in soft tissues in vivo. The waves were introduced using a mechanical stimulus and were assessed using the phase response of the swept source optical coherence tomography signal. The technique was utilized to measure age-related changes in ela...

متن کامل

Biomechanical properties of soft tissue measurement using Optical Coherence Elastography

Optical Coherence Tomography (OCT) provides images at near histological resolution, which allows for the identification of micron sized morphological tissue structures. Optical coherence elastography (OCE) measures tissue displacement and utilizes the high resolution of OCT to generate high-resolution stiffness maps. In this work, we explored the potential of measuring shear wave propagation us...

متن کامل

Optical coherence tomography detection of shear wave propagation in inhomogeneous tissue equivalent phantoms and ex-vivo carotid artery samples.

In this work, we explored the potential of measuring shear wave propagation using optical coherence elastography (OCE) in an inhomogeneous phantom and carotid artery samples based on a swept-source optical coherence tomography (OCT) system. Shear waves were generated using a piezoelectric transducer transmitting sine-wave bursts of 400 μs duration, applying acoustic radiation force (ARF) to inh...

متن کامل

Effect of Localized Mechanical Indentation on Skin Water Content Evaluated Using OCT

The highly disordered refractive index distribution in skin causes multiple scattering of incident light and limits optical imaging and therapeutic depth. We hypothesize that localized mechanical compression reduces scattering by expulsing unbound water from the dermal collagen matrix, increasing protein concentration and decreasing the number of index mismatch interfaces between tissue constit...

متن کامل

Subgingival calculus imaging based on swept-source optical coherence tomography.

We characterized and imaged dental calculus using swept-source optical coherence tomography (SS-OCT). The refractive indices of enamel, dentin, cementum, and calculus were measured as 1.625 ± 0.024, 1.534 ± 0.029, 1.570 ± 0.021, and 2.097 ± 0.094, respectively. Dental calculus leads strong scattering properties, and thus, the region can be identified from enamel with SS-OCT imaging. An extracte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009