A high repetition rate (1 kHz) microcrystal laser for high throughput atmospheric pressure MALDI-quadrupole-time-of-flight mass spectrometry.

نویسندگان

  • John A McLean
  • William K Russell
  • David H Russell
چکیده

Sample throughput has been increased in many areas of proteomics, but the last significant advance in lasers used for matrix-assisted laser desorption/ionization (MALDI) was the introduction of cartridge-type N2 lasers (337 nm, 4-ns pulse widths, 1-30-Hz repetition rates) more than a decade ago. This report describes the application of a 1-kHz repetition rate Nd:YAG laser (355 nm, <500-ps pulse widths) for atmospheric pressure MALDI-QqTOFMS, and data obtained are compared to a conventional nitrogen laser. For example, the signal intensity for angiotensin II using the 1-kHz laser was in some cases enhanced by a factor of 80 and high-quality data could be obtained in as little as 1 s.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrospray sample deposition for matrix-assisted laser desorption/ionization (MALDI) and atmospheric pressure MALDI mass spectrometry with attomole detection limits.

Electrospray sample deposition was explored for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS). In this method, nanoliter volumes of matrix/analyte mixture were electrosprayed from a high voltage biased (1-2 kV) fused-silica capillary onto a grounded MALDI plate mounted 100-500 microm from the capillary outlet. Electrospray deposition with these condi...

متن کامل

Sub-femtomole peptide detection in ion mobility-time-of-flight mass spectrometry measurements.

Sensitivity and detection limit enhancements are obtained for peptides by performing high repetition rate (150 Hz) matrix-assisted laser desorption/ionization (MALDI) coupled with ion mobility-time-of-flight mass spectrometry. Absolute limits of detection (3sigma) for model peptides are on the order of 0.1 fmol of peptide deposited and represent a factor of 40-60 improvement over data obtained ...

متن کامل

Capillary array electrophoresis-MALDI mass spectrometry using a vacuum deposition interface.

We previously introduced a vacuum deposition interface for matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOF MS) on a moving surface (e.g., quartz wheel, Mylar tape, metal target). In our present work, the approach has been extended to demonstrate parallel analysis for multiple on-line infusion MALDI MS and capillary array electrophoresis (CAE)-MALDI MS. In...

متن کامل

Analysis of persistent organic pollutants at sub-femtogram levels using a high-power picosecond laser for multiphoton ionization in conjunction with gas chromatography/time-of-flight mass spectrometry.

A low-energy, high-repetition-rate picosecond laser (40 µJ, 20 kHz, 258 nm) was used for multiphoton ionization (MPI) in gas chromatography/time-of-flight mass spectrometry to quantitatively determine dioxins (DXNs) and polycyclic aromatic hydrocarbons (PAHs). The sensitivity of the technique was compared with that obtained using a high-energy, low-repetition-rate femtosecond laser (86 µJ, 1 kH...

متن کامل

Rapidly switchable matrix-assisted laser desorption/ionization and electrospray quadrupole-time-of-flight mass spectrometry for protein identification.

We describe a new interface for a prototype quadrupole-quadrupole-time-of-flight (TOF) mass spectrometer (Centaur, Sciex) that allows rapid switching between electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) modes of operation. Instrument performance in both modes is comparable (i.e., resolution approximately 10,000 FWHM, mass accuracy <10 ppm, sensitivity ap...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 75 3  شماره 

صفحات  -

تاریخ انتشار 2003