Indican interference with six commercial procedures for measuring total bilirubin.

نویسندگان

  • R Poon
  • I H Hinberg
چکیده

We have studied the effect of indican on six commercial procedures for the measurement of total bilirubin in serum. Total bilirubin measured by the Bilirubin A-Gent (Abbott) 2,4-dichlorophenyl diazonium procedure increased by 50 mg/L for each 1 mmol/L of added indican. Similarly, total bilirubin measured by the Bilirubin C-System (Boehringer Mannheim) 2,5-dichlorophenyl diazonium procedure increased by 33 mg/L per mmol/L of indican. Indican also interfered with the Micro Bilirubin Reagent Set (Harleco) Malloy-Evelyn procedure, but to a much lesser extent. The Jendrassik Bilirubin Reagent System (American Monitor) and a modified Jendrassik-Grof procedure (Hoffmann-LaRoche) adapted to the Cobas Bio analyzer were unaffected by the presence of indican. The amount of interference with the 2,5-dichlorophenyl diazonium procedure increased significantly with color development time and was twice the initial amount after 30 min. Concentrations of indican as high as 0.38 mmol/L have been found in sera of patients with renal failure, which would increase total bilirubin values measured by the first two procedures above by 19 and 12 mg/L, respectively. Users of these procedures should therefore be suspicious of unexpectedly high bilirubin values obtained with sera from patients with chronic renal disease.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EIMER & AMEND PHOTOELECTRIC COLORIMETER For Comparing and Measuring Total Light Transmission and Turbidity of Liquids Applications

Applications The Eimer and Amend Photoelectric Colorimeter can be used wherever "visual" colorimetric methods are employed. Published determinations with this type of instrument include the following: Fluorides, HCN (turbidity), Blood sugar, Urine sugar, Blood creatinine, Cholesterol, Hemoglobin, Indican, Bilirubin, Nitrogen, Blood protein, Urine protein, Spinal fluid protein, Urea, Creatine, G...

متن کامل

Normal range for glucose in urine: age-related changes.

The Du Pont aca “NBIL” test (Du Pont Instruments, Wilmington, DE 19898) also measures bilirubin spectrophotometrically. Figure 2 shows an approximate linear relationship between “apparent” biliburin concentration, as measured with the Bilirubin Stat-Analyzer and the aca NBIL test, vs Liposyn concentration in a neonatal serum sample. This sample without added Liposyn gave identical total bilirub...

متن کامل

Comparative interference by haemolysis in automated assays for bilirubin at multiple analyte concentrations

The negative interference caused by haemolysis in manual bilirubin assays contrasts with the positive interference reported for some automated methods utilizing the same basic chemistry. A comparison was therefore made of the haemolysis interference associated with several automated bilirubin methodologies: multilayer film (Kodak Ektachem- total bilirubin (TBil), direct bilirubin (DBil), conjug...

متن کامل

Centrifugal analyzer method for total bilirubin in serum by use of diazotized 2-chloroaniline-5-sulfonic acid.

We describe two centrifugal analyzer methods for measuring total bilirubin in serum. Diazotized 2-chloroaniline-5-sulfonic acid is used in both. In the first procedure, ethylene glycol and methanol are used as an accelerator solvent; results correlate well with those by a Jendrassik and Grof method adapted to the centrifugal analyzer, but there is considerable hemolysis interference. In the sec...

متن کامل

Bilirubin interference in a peroxidase-coupled procedure for creatinine eliminated by bilirubin oxidase.

A colorimetric peroxidase-coupled procedure for determination of creatinine in human serum and urine is described. A 30-s sample pre-treatment with bilirubin oxidase eliminates interference from endogenous bilirubin. The 4-aminoantipyrine-2-hydroxy-3,5-dichlorobenzenesulfonate chromogen system of this method is about fourfold more sensitive than current procedures that involve monitoring NAD(P)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 31 1  شماره 

صفحات  -

تاریخ انتشار 1985