Effect of baricity on spinal anaesthesia with amethocaine.

نویسندگان

  • D T Brown
  • J A Wildsmith
  • B G Covino
  • D B Scott
چکیده

Amethocaine 1% solution was mixed with equal volumes of water, 0.9% saline or 10% dextrose to prepare respectively, hypobaric, isobaric and hyperbaric solutions which were compared for intradural spinal anaesthesia in 60 patients. Thirty patients received 10 mg and 30 patients received 15 mg of amethocaine. Injections were made with the patients in the lateral recumbent position and the operating table was horizontal during and after injection. Equal numbers of patients and equal numbers of males and females received hypobaric, isobaric and hyperbaric solutions. The mean spread of analgesia after the hyperbaric solution was five dermatomes greater than after the other two solutions, but the extent of analgesia was not significantly different whether amethocaine 10 mg or 15 mg was injected. The mean duration of analgesia after the hyperbaric solution was 285 min compared with 332 min and 360 min after the isobaric and hypobaric solutions respectively. The mean duration of analgesia after amethocaine 15 mg was significantly greater than after 10 mg.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of the baricity of a local anaesthetic agent on sedation with propofol during spinal anaesthesia.

BACKGROUND This study examined the effect of different levels of spinal anaesthesia, induced by solutions of different baricity but containing the same amount of local anaesthetic agent, on the requirement for sedation with propofol. METHODS Thirty-six patients undergoing varicose vein surgery under spinal anaesthesia were randomly allocated to receive tetracaine 15 mg in 3 ml of either gluco...

متن کامل

Visceral pain during caesarean section: effect of varying dose of spinal amethocaine.

The aim of this study was to determine how varying the dose of spinal amethocaine influences the incidence of visceral pain associated with exteriorization of the uterus after delivery. In a double-blind study, we examined the incidence of visceral pain in 40 parturients undergoing Caesarean section under spinal anaesthesia with amethocaine 8, 10, 12 or 14 mg in 2 ml of 5% glucose. The dose of ...

متن کامل

Spinal anaesthesia with 0.75% bupivacaine and 0.5% amethocaine in 5% glucose.

Three millititre of 0.75% plain bupivacaine and 0.5% amethocaine 3 ml in 5% glucose were used for spinal anaesthesia and compared in a double-blind study of 20 patients undergoing urological surgery. The onset time to maximum cephalad spread of sensory analgesia was approximately 45 min for bupivacaine and approximately 30 min in the amethocaine group (ns). The mean maximum spread of sensory an...

متن کامل

Acid-base state of cerebrospinal fluid during pregnancy and its effect on spread of spinal anaesthesia.

To assess the possible relationship between changes in acid-base state of cerebrospinal fluid (CSF) and enhanced spread of spinal anaesthesia during pregnancy, we have measured CSF pH, carbon dioxide tension (PCO2) and HCO3- values in 73 women undergoing spinal anaesthesia with hyperbaric amethocaine 8 mg. Patients were allocated to one of four groups according to gestational period: non-pregna...

متن کامل

Topical amethocaine in strabismus surgery.

A randomized study was performed to assess the effect of topical 1% amethocaine hydrochloride on postoperative analgesia requirements after strabismus surgery. Forty children scheduled for elective operation were allocated randomly to receive either topical amethocaine or normal saline. Postoperative analgesia was evaluated with the use of a four-point assessment score and analgesic requirement...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 52 6  شماره 

صفحات  -

تاریخ انتشار 1980