Peritoneal equilibration test at home.

نویسندگان

  • Yasuki Hashimoto
  • Akira Mima
چکیده

The peritoneal equilibration test (PET) has been widely used as a standardized means for estimating solute transport. However, the procedure is rather complex, and patients must spend more than half a day in the hospital. The fast PET is an alternative method, but the results are not reliable in patients whose peritoneal catheters drain poorly. We postulated that patients could perform the PET at home if educated well about the procedure. To that purpose, we prepared three types of visual aids that introduce the PET procedure: a VCR tape, a DVD disc, and a brochure with photographs. Equilibration tests were performed using the twin-bag system. For making fluid level indicator lines (200 mL and 10 mL), patients are given a guide sheet on which the fresh dialysate bag is placed. After an 8- to 12-hour overnight dwell, the dwelled dialysate is drained completely into the empty bag. Immediately after the patient infuses 2 L of fresh 2.5% glucose dialysis solution, 200 mL of that solution is drained into the bag on which the two fluids levels were previously marked. After mixing, about 190 mL of the dialysate is re-infused, and the remaining 10 mL (the amount indicated by a guide mark at the corner) is left within the bag. After a 4-hour dwell, the dialysate is completely drained into another twin-bag. A standard PET was also performed on a different day, and the data were compared with those from the home PET. Significant correlations were seen in D/D0 and in drain volume between the home PET and the standard PET (n = 10; D/D0: 0.385 +/- 0.054 vs. 0.371 +/- 0.052 respectively, r = 0.872, p = 0.0004; drain volume: 2340 +/- 123 mL vs. 2372 +/- 90 mL respectively, r = 0.788, p = 0.0048). We conclude that the home PET is a clinically useful alternative to the standard PET, saving time and labor while maintaining accuracy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ANCA-associated vasculitis and anti-GBM disease: the experience in China.

during CAPD measured with intraperitoneal dextran 70. ASAIO Trans 1991; 37: 662–667 34. Van Biesen W, Carlsson O, Bergia R et al. Personal dialysis capacity (PDC(TM)) test: a multicentre clinical study. Nephrol Dial Transplant 2003; 18: 788–796 35. Van Biesen W, Van der Tol A, Veys N et al. The personal dialysis capacity test is superior to the peritoneal equilibration test to discriminate infl...

متن کامل

Multidirectional approach to study peritoneal dialysis fluid biocompatibility in a chronic peritoneal dialysis model in the rat.

BACKGROUND Peritoneal dialysis causes the functional and morphological changes in the peritoneum that result from the bioincompatibility of dialysis solutions. We present a model of chronic peritoneal dialysis in the rat that can be used for testing the biocompatibility of dialysis fluids. Methods and Results. Long-term exposure of the peritoneum to dialysis solutions can be performed in rats w...

متن کامل

A longitudinal change of peritoneal equilibration test results in peritoneal dialysis patients aged 60 years and above: a 4-year observation study in comparison with a younger group.

BACKGROUND The number of elderly people with end-stage renal disease has grown in developed countries and medical teams now face the choice of dialysis therapy in elderly patients. In the present study, we retrospectively analyzed two peritoneal dialysis (PD) patients, of different ages, who were treated at the same unit by the same PD team of doctors and nurses. Our purpose was to study perito...

متن کامل

Estimates of peritoneal membrane function--new insights.

The most widely used peritoneal function test is the peritoneal equilibration test (PET), developed and described by Twardowski in 1987. The test was originally performed using a 2.27% glucose solution and focused on transport of small solutes. With the test, categorization of patients was possible into high, average and low transporters. However, to detect clinically significant ultrafiltratio...

متن کامل

Prothrombin fragment 1 + 2 (F1 + 2) in effluent is a useful marker for peritoneal permeability in peritoneal dialysis patients using neutral dialysate.

To clarify the influence of neutral dialysate (ND) on peritoneum, we examined changes in peritoneal permeability and in various markers of the coagulation and fibrinolytic system in effluent and the correlations between peritoneal permeability and those markers in peritoneal dialysis (PD) patients using ND. We evaluated 14 patients (8 men, 6 women; mean age: 58.6 +/- 12.0 years) who started PD ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Advances in peritoneal dialysis. Conference on Peritoneal Dialysis

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2002