Cryoablation time-dependent dose–response effect at minimal temperatures (−80°C): an experimental study

نویسندگان

  • Felipe Atienza
  • Jesús Almendral
  • Damián Sánchez-Quintana
  • Matilde Zaballos
  • Margarita Murillo
  • Concepción Jimeno
  • Verónica Parra
  • Francisco Fernández-Avilés
چکیده

AIMS To establish a temporal safety window for cryoablation at minimal temperatures and to assess the electrophysiological and histological changes as a function of the application duration. METHODS AND RESULTS Twenty mini-pigs underwent AV nodal cryoablation at -80 degrees C without prior cryomapping. The duration of the cryoapplication following atrioventricular block (AVB) was randomized to 0, 10, 20, 40, or 60 s. Atrioventricular block was obtained in all animals after a median of 3 (1-8 interquartile range) applications. One week later, AV nodal conduction fully recovered in animals with application duration <10 s, whereas persistent AVB incidence increased as a function of time in animals with longer applications duration. Cryoablation application duration following AVB was the only independent predictor of persistent AVB (OR, 1.116; 95% CI, 1.013-1.229; P = 0.026). There was no difference in lesion location or size between animals with vs. those without persistent AVB at 1 week. However, animals randomized to longer application duration demonstrated higher degree of cell destruction and fibrotic content. CONCLUSION In this closed-chest pig model, there was a relation between cryoapplication duration following AVB at -80 degrees C and recovery of conduction. A safety window of at least 10 s was observed in all cases.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Process Optimization in Vacuum Frying of Kiwi Slices Using Response Surface Methodology

ABSTRACT: Vacuum deep-fat frying is a new technology that can be used to improve the quality attributes of fried food because of the low temperatures employed and minimal exposure to oxygen. In this paper the effect of frying process parameters, namely frying time, frying temperature and pressure on the quality factors of fried kiwi slices was studied. A laboratory scale vacuum frying apparatus...

متن کامل

Inhibitory Effect of Tricalcium Phosphate Sintered at Different Temperatures on Human Breast Cancer Cell Line MCF-7

Abstract Introduction: Achievement of new drugs with minimal side effects is a important goal in the cancer treatment due to irreversible side effects of conventional drugs. Tricalcium phosphates as natural bone components have unique characteristics including excellent biocompatibility, high biosorption and superior bioactivity. This research aimed at investigating the inhibitory effect of tr...

متن کامل

Inhibitory Effect of Tricalcium Phosphate Sintered at Different Temperatures on Human Breast Cancer Cell Line MCF-7

Abstract Introduction: Achievement of new drugs with minimal side effects is a important goal in the cancer treatment due to irreversible side effects of conventional drugs. Tricalcium phosphates as natural bone components have unique characteristics including excellent biocompatibility, high biosorption and superior bioactivity. This research aimed at investigating the inhibitory effect of tr...

متن کامل

Comparative Study of the Effect of Storage Environment Temperature on the Accuracy of Hygedent and Chromogel Alginate Impression Materials

Background and Aim: Considering the lack of sufficient and even contradictory studies on the effect of temperature-dependent dimensional changes of alginate before pouring, this study aimed to investigate the effect of storage temperature of Hygedent and Chromogel alginate molds on dimensional stability.  Materials and Methods: In this in-vitro experimental study, dimensional changes of two t...

متن کامل

تأثیر عملیات پخت بر پاسخ ترمولومینسانس هیدروکسی اپاتیت نانوساختار فراهم‌‌شده به روش هیدرولیز از دیدگاه دزیمتری

In this study, the pure nano-structure hydroxyl apatite samples were synthesized via hydrolysis method. The powder samples were sintered at various temperatures of 500&deg;C, 700&deg;C and 900&deg;C in a furnace. X-ray diffraction (XRD) and Fourier transform infra-red (FTIR) spectroscopy systems were used to characterize the synthsized samples. Comparison of the glow curves shows that the most ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2009