Automatic XAFS measurement system developed at BL14B2 in SPring-8

نویسندگان

  • Hiroshi Oji
  • Yosuke Taniguchi
  • Sayaka Hirayama
  • Hironori Ofuchi
  • Masashi Takagaki
  • Tetsuo Honma
چکیده

A novel XAFS measurement system has been developed in which XAFS measurements can be performed including sample-loading and detector adjustments. With this system, XAFS measurements of up to 80 samples in both transmission and fluorescence modes can be carried out. The adjustment of the optical components has also been automated. It not only saves manpower and measurement time, but also improves the accuracy and reliability of sample alignments.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid and sensitive XAFS using a tunable X-ray undulator at BL10XU of SPring-8.

The design and performance of the high-brilliance XAFS facility at BL10XU of SPring-8, aimed at rapid and sensitive measurement of X-ray absorption fine structure (XAFS), is reported. Both undulator gap and double-crystal monochromator have been successfully controlled covering a wide energy range (5-30 keV). A versatile goniometer system, consisting of two independent high-precision goniometer...

متن کامل

Improvement in XAFS beamline BL01B1 at SPring-8

Beamline BL01B1 was constructed for conventional XAFS measurements using a bending magnet light source at SPring-8 in 1997 [1]. BL01B1 covers a wide energy range from 3.8 to 113 keV using an adjustable inclined double-crystal monochromator and a double mirror system. Here, we describe a newly developed apparatus and the current status of the BL01B1. A time-efficient QEXAFS method was developed ...

متن کامل

SPring-8 BL36XU: Catalytic Reaction Dynamics for Fuel Cells

A tapered undulator beamline BL36XU was constructed at SPring-8 to conduct structural and electronic analysis of dynamic events on polymer electrolyte fuel cell (PEFC) cathode catalysts for the development of next-generation PEFCs. BL36XU provides various time and spatially resolved XAFS techniques in an energy range from 4.5 to 35 keV for investigating PEFCs under the operating conditions. In ...

متن کامل

A Semi-Automatic Algorithm for Estimating Cobb Angle

Background: Scoliosis is the most common type of spinal deformity. A universal and standard method for evaluating scoliosis is Cobb angle measurement, but several studies have shown that there is intra- and inter- observer variation in measuring cobb angle manually.Objective: Develop a computer- assisted system to decrease operator-dependent errors in Cobb angle measurement.Methods: The spinal ...

متن کامل

XAFS analysis of triiodide ion in solutions.

Iodine K-edge XAFS of triiodide ions in various solvents were measured at SPring-8 BL01B1 and analyzed. Though the anion takes a linear and symmetric form, the second peak expected from enhanced multiple scatterings can be hardly observed because of its large vibrations. The bond distances and the Debye-Waller factors for the I-I couple vary when protic solvents were used and they were similar ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 19  شماره 

صفحات  -

تاریخ انتشار 2012