Sensitivity and performance time in MRI dephasing artifact reduction methods.

نویسندگان

  • Y Z Wadghiri
  • G Johnson
  • D H Turnbull
چکیده

Although shimming can improve static field inhomogeneity, local field imperfections induced by tissue susceptibility differences cannot be completely corrected and can cause substantial signal loss in gradient echo images through intravoxel dephasing. Dephasing increases with voxel size so that one simple method of reducing the effect is to use thin slices. Signal-to-noise ratio (SNR) can then be increased by averaging over the subslices to form the final, thick slice. We call this method subslice averaging or SSAVE. Alternatively, a range of different amplitude slice select rephase gradients can be used to compensate for different susceptibility induced gradient offsets. The final image can then be formed by combining individual images in a variety of ways: summation, summation of the squares of the images, forming the maximum intensity projection of the image set, and Fourier transformation followed by summation. We show here that, contrary to previous claims, the theoretical sensitivity (i.e., SNR divided by the square root of the imaging time) of all these alternative methods is very similar. However, performance time (i.e., minimum-imaging time) of the simplest method, SSAVE, is much shorter than that of alternatives. This is confirmed experimentally on phantoms and anesthetized mice. Magn Reson Med 45:470-476, 2001.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Through-slice dephasing for eddy current artifact reduction in bSSFP

Eddy current effects can severely degrade image quality when using balanced steady-state free precession imaging with rapidly varying phase encode ordering schemes, which have common use in cardiac cine MRI. In this work, we explore and characterize a previouslyproposed technique, through-slice dephasing, as the sole technique for eddy current artifact removal. We demonstrate that artifacts var...

متن کامل

Improving the Performance of ICA Algorithm for fMRI Simulated Data Analysis Using Temporal and Spatial Filters in the Preprocessing Phase

Introduction: The accuracy of analyzing Functional MRI (fMRI) data is usually decreases in the presence of noise and artifact sources. A common solution in for analyzing fMRI data having high noise is to use suitable preprocessing methods with the aim of data denoising. Some effects of preprocessing methods on the parametric methods such as general linear model (GLM) have previously been evalua...

متن کامل

Reduction of Susceptibility Artifacts in MRI using Narrowband Excitation

Introduction Off-resonance effects related to susceptibility differences in objects are a major headache in gradient-echo imaging techniques. They lead to intra-voxel dephasing during the delay time between excitation and reception (TE), resulting in signal drop-outs. In addition, phase accumulation during the acquisition leads to image artifacts, which are particularly severe in fast imaging t...

متن کامل

A New Method for Metal Artifact Reduction in CT Scan Images

Introduction In CT imaging, metallic implants inside the tissues cause metal artifact that reduce the quality of image for diagnosis. In order to reduce the effect of this artifact, a new method with more appropriate results has been presented in this research work. Materials and Methods The presented method comprised of following steps: a) image enhancement and metal areas extraction, b) sinog...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 2001