Long-term assessment of a novel biodegradable paclitaxel-eluting coronary polylactide stent.

نویسندگان

  • Felix Vogt
  • Andreas Stein
  • Gösta Rettemeier
  • Nicole Krott
  • Rainer Hoffmann
  • Jürgen vom Dahl
  • Anja-Katrin Bosserhoff
  • Walter Michaeli
  • Peter Hanrath
  • Christian Weber
  • Rüdiger Blindt
چکیده

AIM The aim of this study was to assess technical feasibility, biocompatibility, and impact on coronary stenosis of a new biodegradable paclitaxel-loaded polylactide stent. Due to high rates of in-stent restenosis and permanent nature of metal stent implants, synthetic polymers have been proposed as surrogate materials for stents and local delivery systems for drugs. Paclitaxel was shown to inhibit vascular smooth muscle cell proliferation and migration. METHODS AND RESULTS A novel biodegradable double-helical stent was manufactured using controlled expansion of saturated polymers (CESP) for the moulding of a bioresorbable poly(D,L)-lactic acid (PDLLA). A modified balloon catheter for stent deployment was developed according to the mechanical stent properties. Twelve paclitaxel-loaded (170 microg) polylactide stents, 12 unloaded polylactide stents, and 12 316L bare metal stents were deployed in porcine coronary arteries of 36 animals. Six pigs of each group were sacrificed after 3 weeks and 3 months, respectively, for every setting. Drug release kinetics as well as histomorphometrical and histopathological analyses were performed. A slow paclitaxel release kinetic for more than 2 months and therapeutic tissue concentrations were demonstrated. Coronary stenosis after implantation of paclitaxel-loaded stents (30+/-5% or 49+/-4%) was significantly inhibited compared to unloaded PDLLA stents (65+/-10%, P=0.021 or 71+/-4%, P=0.004) and metal stents (53+/-6% or 68+/-8%, P=0.029 and P=0.020) after 3 weeks or 3 months. Early complete endothelialisation was shown. Nevertheless, a local inflammatory response to the polylactide as a result of the polymer resorption process was observed. CONCLUSIONS This novel polylactide stent showed sufficient mechanic stability, and by incorporation of paclitaxel, a significant potential to reduce restenosis development after vascular intervention was seen.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel paclitaxel-eluting stent with an ultrathin abluminal biodegradable polymer 9-month outcomes with the JACTAX HD stent.

OBJECTIVES The JACTAX HD trial ("JACTAX" Trial Drug Eluting Stent Trial) evaluated the safety and clinical performance of a novel JACTAX HD (Boston Scientific Corporation, Natick, Massachusetts) paclitaxel-eluting stent (PES) in de novo coronary lesions. BACKGROUND The JACTAX HD (Boston Scientific) stent consists of a pre-crimped bare-metal Liberté (Boston Scientific) stent coated on its ablu...

متن کامل

Evaluation of a novel slow-release paclitaxel-eluting stent with a bioabsorbable polymeric surface coating.

OBJECTIVES We sought to evaluate a new second-generation drug-eluting stent (DES), comprising a slow-release biodegradable polylactide coglycolide (PLGA) polymer and low-dose paclitaxel on a thin-strut cobalt chromium stent platform, in a clinically relevant animal model. BACKGROUND Our previous work demonstrated subacute vascular toxicity and necrosis triggering late excess neointima in pig ...

متن کامل

Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

متن کامل

Baremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS

Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...

متن کامل

Promoting endothelial recovery and reducing neointimal hyperplasia using sequential-like release of acetylsalicylic acid and paclitaxel-loaded biodegradable stents

INTRODUCTION This work reports on the development of a biodegradable dual-drug-eluting stent with sequential-like and sustainable drug-release of anti-platelet acetylsalicylic acid and anti-smooth muscle cell (SMC) proliferative paclitaxel. METHODS To fabricate the biodegradable stents, poly-L-lactide strips are first cut from a solvent-casted film. They are rolled onto the surface of a metal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 25 15  شماره 

صفحات  -

تاریخ انتشار 2004