Mie light scattering calculations for an Indian age-related nuclear cataract with a high density of multilamellar bodies
نویسندگان
چکیده
PURPOSE Multilamellar bodies (MLBs) are lipid-coated spheres (1-4 microm in diameter) found with greater frequency in the nuclear region of human age-related cataracts compared with human transparent lenses. Mie light scattering calculations have demonstrated that MLBs are potential sources of forward light scattering in human age-related nuclear cataracts due to their shape, size, frequency, and cytoplasmic contents, which often differ in refractive index from their surroundings. Previous studies have used data from several non-serial tissue sections viewed by light microscopy to extrapolate a volume and have assumed that MLBs are random in distribution. Currently, confocal microscopy is being used to examine actual tissue volumes from age-related nuclear cataracts and transparent lenses collected in India to confirm MLB shape, size, frequency, and randomness. These data allow Mie scattering calculations to be done with directly observed MLBs in intact tissue. METHODS Whole Indian donor lenses and Indian lens nuclei after extracapsular cataract extraction were immersion-fixed in 10% formalin for 24 h and in 4% paraformaldehyde for 24 h before sectioning with a Vibratome. The 160 microm thick sections were stained for 24 h in the lipid dye DiI (1,1'-dilinoleyl-3,3,3',3' tetramethylindocarbocyanine, 4-chlorobenzenesulfonate), washed, stabilized in Permount under coverslips and examined with a Zeiss LSM 510 confocal microscope. Individual volumes of tissue (each typically 500,000 microm(3)) were examined using a plan-apochromat 63X oil (NA=1.4) lens. Other lenses were prepared for electron microscopy and histological examination using previously described procedures. RESULTS Analysis of tissue volumes within Indian age-related nuclear cataracts and transparent lenses has confirmed that most MLBs are 1-4 microm in diameter and typically spherical with some occurring as doublets or in clusters. Most Indian cataracts and transparent lenses are similar to samples obtained in the United States. One cataract contained as many as 400,000 MLBs per mm(3) -100 times more than in cataracts collected in the United States. Pairwise distribution analysis has revealed that MLBs even in this exceptional case are found with a distribution that appears to be random. Mie calculations indicate that more than 90% of the incident light could be scattered by the high density of MLBs. CONCLUSIONS An important finding was that one advanced Indian cataract contained many more MLBs than cataracts examined from India and previously from the United States. This indicates that specific conditions or susceptibilities may exist that promote the formation of excessive MLBs. Based on the extremely high frequency, as well as their spherical shape, large size, and apparent random distribution, the MLBs are predicted according to Mie light scattering calculations to cause high amounts of forward scattering sufficient to produce nuclear opacity.
منابع مشابه
Multilamellar spherical particles as potential sources of excessive light scattering in human age-related nuclear cataracts.
The goal of this project was to determine the relative refractive index (RI) of the interior of multilamellar bodies (MLBs) compared to the adjacent cytoplasm within human nuclear fiber cells. MLBs have been characterized previously as 1-4 μm diameter spherical particles covered by multiple lipid bilayers surrounding a cytoplasmic core of variable density. Age-related nuclear cataracts have mor...
متن کاملDistribution, spherical structure and predicted Mie scattering of multilamellar bodies in human age-related nuclear cataracts.
PURPOSE To characterize multilamellar bodies (MLBs), determine their distribution along the optic axis and predict their potential Mie scattering within human age-related nuclear cataracts. Previous studies restricted to the equatorial plane have shown that MLBs are rare spherical objects that are 1-4 microm in diameter and covered by multiple layers of thin lipid-rich membranes. METHODS Eigh...
متن کاملPredicted light scattering from particles observed in human age-related nuclear cataracts using mie scattering theory.
PURPOSE To employ Mie scattering theory to predict the light-scattering from micrometer-sized particles surrounded by lipid shells, called multilamellar bodies (MLBs), reported in human age-related nuclear cataracts. METHODS Mie scattering theory is applicable to randomly distributed spherical and globular particles separated by distances much greater than the wavelength of incident light. Wi...
متن کاملElectron tomography of fiber cell cytoplasm and dense cores of multilamellar bodies from human age-related nuclear cataracts.
Human nuclear cataract formation is a multi-factorial disease with contributions to light scattering from many cellular sources that change their scattering properties over decades. The aging process produces aggregation of cytoplasmic crystallin proteins, which alters the protein packing and texture of the cytoplasm. Previous studies of the cytoplasmic texture quantified increases in density f...
متن کاملA Computer Modeling of Mie-Scattering by Spherical Droplets Within the Atmosphere
The Earth’s atmosphere is an environment replete with particles of differ-ent sizes with various refractive indices which affect the light radiation traveling through it. The Mie scattering theory is one of the well-known light scattering techniques ap-plicable to modeling of electromagnetic scattering from tiny atmospheric particles or aerosols floating in the air or within the clouds. In this...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Molecular Vision
دوره 14 شماره
صفحات -
تاریخ انتشار 2008