Development and comparison of a rapid isothermal nucleic acid amplification test for typing of herpes simplex virus types 1 and 2 on a portable fluorescence detector.
نویسندگان
چکیده
We have developed a rapid and simple molecular test, the IsoGlow HSV Typing assay, for the detection and typing of herpes simplex virus (type 1 and 2) from genital or oral lesions. Clinical samples suspended in viral transport mediums are simply diluted and then added to a helicase-dependent amplification master mix. The amplification and detection were performed on a portable fluorescence detector called the FireFly instrument. Detection of amplification products is based on end-point analysis using cycling probe technology. An internal control nucleic acid was included in the amplification master mix to monitor the presence of amplification inhibitors in the samples. Because the device has only two fluorescence detection channels, two strategies were developed and compared to detect the internal control template: internal control detected by melting curve analysis using a dual-labeled probe, versus internal control detection using end-point fluorescence release by a CPT probe at a lower temperature. Both have a total turnaround time of about 1 hour. Clinical performance relative to herpes viral culture was evaluated using 176 clinical specimens. Both formats of the IsoGlow HSV typing assay had sensitivities comparable to that of the Food and Drug Administration-cleared IsoAmp HSV (BioHelix Corp., Beverly MA) test and specificity for the two types of HSV comparable to that of ELVIS HSV (Diagnostic Hybrids, Athens, OH).
منابع مشابه
Loop-Mediated Isothermal Amplification (LAMP) for the Rapid Diagnosis of Herpes Simplex Virus Type 1 (HSV-1)
Background and Aims: considering difficulties in usual laboratory methods in detection of viral infections, improved DNA-based diagnostic techniques are more reliable. Loop mediated isothermal amplification method (LAMP) is a nucleic acid amplification method that amplifies DNA using six primers which has been developed to diagnose viruses as a rapid and high efficiency test. In this study, the...
متن کاملA Review of the Classical and Molecular Diagnostic Methods of Herpes Simplex Virus
Human Herpes Viruses (HSV) contain eight pathogens. HSV is one of the most widespread viruses in the world and due to the simplicity of the way of transmission the number of people infected with the virus has increased in per year. The virus creates a wide range of diseases, including mucosal herpes infections and deadly herpes simplex encephalitis. Today, for the diagnosis of HSV infection se...
متن کاملDetermination of Herpetic Keratitis Frequency Using Loop Mediated Isothermal Amplification (LAMP) Method in Isfahan, Iran
Herpetic keratitis which is resulted from herpes simplex virus type I, is considered the most common cause of corneal blindness that needs being diagnosed and treated in order to prevent irreversible eye effects. The best method to diagnose it is molecular method which has high sensitivity and exclusivity. The current study was done on 25 eye samples collected from patients referred to the Feyz...
متن کاملComparative clinical evaluation of the IsoAmp(®) HSV Assay with ELVIS(®) HSV culture/ID/typing test system for the detection of herpes simplex virus in genital and oral lesions.
BACKGROUND The novel IsoAmp(®) HSV Assay employs isothermal helicase-dependent nucleic acid amplification and a user-friendly disposable test device to achieve rapid (<1.5h), on-demand qualitative detection of herpes simplex virus (HSV) types 1 and 2 in oral and genital lesions. OBJECTIVES To compare performance of the IsoAmp(®) HSV Assay with the ELVIS(®) HSV ID/typing (shell-vial culture an...
متن کاملDetermination of Herpetic Keratitis Frequency Using Loop Mediated Isothermal Amplification (LAMP) Method in Isfahan, Iran
Herpetic keratitis which is resulted from herpes simplex virus type I, is considered the most common cause of corneal blindness that needs being diagnosed and treated in order to prevent irreversible eye effects. The best method to diagnose it is molecular method which has high sensitivity and exclusivity. The current study was done on 25 eye samples collected from patients referred to the Feyz...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of molecular diagnostics : JMD
دوره 14 6 شماره
صفحات -
تاریخ انتشار 2012