A Systematic Method for Tracer Test Analysis: an Example Using Beowawe Tracer Data
نویسنده
چکیده
Quantitative analysis of tracer data using moment analysis requires a strict adherence to a set of rules which include data normalization, correction for thermal decay, deconvolution, extrapolation, and integration. If done correctly, the method yields specific information on swept pore volume, flow geometry and fluid velocity, and an understanding of the nature of reservoir boundaries. All calculations required for the interpretation can be done in a spreadsheet. The steps required for moment analysis are reviewed in this paper. Data taken from the literature is used in an example calculation.
منابع مشابه
ارزیابی عملکرد هودهای آزمایشگاهی براساس استاندارد ASHRAE 110 در
Background and Aim: Laboratory fume-hoods are the first-level protection for the laboratory staff against hazardous chemical pollutants. Considering the large numbers of personnel, especially in petrochemical industry laboratories, this project was carried out in order to assess the performance of laboratory hoods based on tracer gas (SF6).Materials and Methods: In this project 22 hoods in the ...
متن کاملCalibration curves for on-line leakage detection using radiotracer injection method
One of the most important requirements for industrial pipelines is the leakage detection. In this paper, detection of leak and determination of its amount using radioactive tracer injection method has been simulated by Monte Carlo MCNP code. The detector array included two NaI (Tl) detectors which were located before and after the considered position, measure emitted gamma from radioactive trac...
متن کاملThe Effect of Different Stabilizers on Stability of Horseradish Peroxidase- Bovine Serum Albumin-Aflatoxin B1, a Conjugated Tracer for Detection of Aflatoxin B1 in Immunoassay-Based Methods
Aflatoxins are a group of fungal toxic metabolites, which are contaminated certain food commodities. ELISA is one of the sensitive methods for detection of aflatoxins. Preparation and stabilizing of a proper conjugated tracer for detection of aflatoxins is probably the main step for designing an ELISA method. In current study, different stabilizers were applied to stabilize a newly prepared con...
متن کاملAssessment of mediastinal tumors using SUVmax and volumetric parameters on FDG PET/CT
Objective(s): This study aimed to evaluate the role of pretreatment SUVmax and volumetric FDG positron emission tomography (PET) parameters in the differentiation between benign and malignant mediastinal tumors. In addition, we investigated whether pretreatment SUVmax and volumetric FDG-PET parameters could distinguish thymomas from thymic carcinomas, and low-risk from high-risk thymomas.Method...
متن کاملThe Effect of Different Stabilizers on Stability of Horseradish Peroxidase- Bovine Serum Albumin-Aflatoxin B1, a Conjugated Tracer for Detection of Aflatoxin B1 in Immunoassay-Based Methods
Aflatoxins are a group of fungal toxic metabolites, which are contaminated certain food commodities. ELISA is one of the sensitive methods for detection of aflatoxins. Preparation and stabilizing of a proper conjugated tracer for detection of aflatoxins is probably the main step for designing an ELISA method. In current study, different stabilizers were applied to stabilize a newly prepared con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005