Spatial orientation in bone samples and Young's modulus.

نویسندگان

  • W G M Geraets
  • L J van Ruijven
  • J G C Verheij
  • P F van der Stelt
  • T M G J van Eijden
چکیده

Bone mass is the most important determinant of the mechanical strength of bones, and spatial structure is the second. In general, the spatial structure and mechanical properties of bones such as the breaking strength are direction dependent. The mean intercept length (MIL) and line frequency deviation (LFD) are two methods for quantifying directional aspects of the spatial structure of bone. Young's modulus is commonly used to describe the stiffness of bone, which is also a direction-dependent mechanical property. The aim of this article is to investigate the relation between MIL and LFD on one hand and Young's modulus on the other. From 11 human mandibular condyles, 44 samples were taken and scanned with high-resolution computer tomography equipment (micro-CT). For each sample the MIL and LFD were determined in 72602 directions distributed evenly in 3D space. In the same directions Young's modulus was determined by means of the stiffness tensor that had been determined for each sample by finite element analysis. To investigate the relation between the MIL and LFD on one hand and Young's modulus on the other, multiple regression was used. On average the MIL accounted for 69% of the variance in Young's modulus in the 44 samples and the LFD accounted for 72%. The average percentage of variance accounted for increased to 80% when the MIL was combined with the LFD to predict Young's modulus. Obviously MIL and LFD to some extent are complementary with respect to predicting Young's modulus. It is known that directional plots of the MIL tend to be ellipses or ellipsoids. It is speculated that ellipsoids are not always sufficient to describe Young's modulus of a bone sample and that the LFD partly compensates for this.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

UvA - DARE ( Digital Academic Repository ) Spatial orientation in bone samples and Young ' s modulus

Bone mass is the most important determinant of the mechanical strength of bones and spatial structure is the second. In general the spatial structure and mechanical properties of bones such as the breaking strength are directional dependent. The Mean Intercept Length (MIL) and Line Frequency Deviation (LFD) are two methods for quantifying directional aspects of the spatial structure of bone. Th...

متن کامل

Material Properties of the Mandibular Trabecular Bone.

The present paper introduces a numerical simulation aided, experimental method for the measurement of Young's modulus of the trabecular substance in the human mandible. Compression tests were performed on fresh cadaveric samples containing trabecular bone covered with cortical layer, thus avoiding the destruction caused by the sterilization, preservation, and storage and the underestimation of ...

متن کامل

Effects of Reorientation of Graphene Platelets (GPLs) on Young’s Modulus of Polymer Composites under Bi-Axial Stretching

Effects of bi-axial stretching induced reorientation of graphene platelets (GPLs) on the Young's modulus of GPL/polymer composites is studied by Mori-Tanaka micromechanics model. The dispersion state of the GPLs in polymer matrix is captured by an orientation distribution function (ODF), in which two Euler angles are used to identify the orientation of the GPLs. Compared to uni-axial stretching...

متن کامل

Intrinsic mechanical properties of trabecular calcaneus determined by finite-element models using 3D synchrotron microtomography.

To determine intrinsic mechanical properties (elastic and failure) of trabecular calcaneus bone, chosen as a good predictor of hip fracture, we looked for the influence of image's size on a numerical simulation. One cubic sample of cancellous bone (9 x 9 x 9 mm(3)) was removed from the body of the calcaneus (6 females, 6 males, 79+/-9 yr). These samples were tested under compressive loading. Be...

متن کامل

Titanium-Based Biomaterials for Preventing Stress Shielding between Implant Devices and Bone

β-type titanium alloys with low Young's modulus are required to inhibit bone atrophy and enhance bone remodeling for implants used to substitute failed hard tissue. At the same time, these titanium alloys are required to have high static and dynamic strength. On the other hand, metallic biomaterials with variable Young's modulus are required to satisfy the needs of both patients and surgeons, n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanics

دوره 41 10  شماره 

صفحات  -

تاریخ انتشار 2008