Comparison of multileaf collimator and conventional circular collimator systems in Cyberknife stereotactic radiotherapy

نویسندگان

  • Taro Murai
  • Yukiko Hattori
  • Chikao Sugie
  • Hiromitsu Iwata
  • Michio Iwabuchi
  • Yuta Shibamoto
چکیده

Multileaf collimator (MLC) technology has been newly introduced with the Cyberknife system. This study investigated the advantages of this system compared with the conventional circular collimator (CC) system. Dosimetric comparisons of MLC and CC plans were carried out. First, to investigate suitable target sizes for the MLC mode, MLC and CC plans were generated using computed tomography (CT) images from 5 patients for 1, 3, 5 and 7 cm diameter targets. Second, MLC and CC plans were compared in 10 patients, each with liver and prostate targets. For brain targets, doses to the brain could be spared in MLC plans better than in CC plans (P ≤ 0.02). The MLC mode also achieved more uniform dose delivery to the targets. The conformity index in MLC plans was stable, irrespective of the target size (P = 0.5). For patients with liver tumors, the MLC mode achieved higher target coverage than the CC mode (P = 0.04). For prostate tumors, doses to the rectum and the conformity index were lowered in MLC plans compared with in CC plans (P ≤ 0.04). In all target plans, treatment times in MLC plans were shorter than those in CC plans (P < 0.001). The newly introduced MLC technology can reduce treatment time and provide favorable or comparable dose distribution for 1-7 cm targets. In particular, the MLC mode has dosimetric advantage for targets near organs at risk. Therefore, the MLC mode is recommended as the first option in stereotactic body radiotherapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the clinical advantages of a robotic linac equipped with a multileaf collimator in the treatment of brain and prostate cancer patients

The purpose of this study was to evaluate the performance of a commercially avail-able CyberKnife system with a multileaf collimator (CK-MLC) for stereotactic body radiotherapy (SBRT) and standard fractionated intensity-modulated radiotherapy (IMRT) applications. Ten prostate and ten intracranial cases were planned for the CK-MLC. Half of these cases were compared with clinically approved SBRT ...

متن کامل

Radiation transmission, leakage and beam penumbra measurements of a micro‐multileaf collimator using GafChromic EBT film

Micro-multileaf collimator systems coupled to linear accelerators for radioneurosurgery treatments require a rigorous dosimetric characterization in order to be used in 3D conformal and intensity modulated stereotactic radiosurgery and radiotherapy applications. This characterization involves high precision measurements of leaf transmission, leakage and beam penumbra through the collimation sys...

متن کامل

Measurement of beam-axis displacement from the isocenter during three-dimensional conformal radiosurgery with a micro-multileaf collimator.

We describe the displacement of the beam-axis from the planning isocenter in clinical situations during three-dimensional conformal radiosurgery using an Acculeaf bi-directional micro-multileaf collimator. The displacements were recorded for 64 ports using a video imaging system and a stereotactic arc. The mean displacement was 0.41+/-0.25 mm.

متن کامل

Robotic radiosurgery versus micro-multileaf collimator: a dosimetric comparison for large or critically located arteriovenous malformations

BACKGROUND Stereotactic irradiation of large or critically located arteriovenous malformations (AVMs) is a special challenge for clinicians and radiation physicists. To date, no comprehensive comparison of two linac-based radiosurgery systems used for hypofractionated radiotherapy of large AVMs was published. The aim of the study was to compare dose distributions between CyberKnife (CK) system ...

متن کامل

The Cyberknife ® M 6 TM Radiosurgery System Jeffrey

Lancaster General Health is the first institution in the United States to have the next generation CyberKnife made by Accuray Inc., the M6 series (Fig. 1). The CyberKnife utilizes non-invasive stereotactic radiosurgery to deliver precise, high doses of radiation to targets anywhere in the body. Recent studies have shown that stereotactic radiosurgery offers high rates of tumor control with mini...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 58  شماره 

صفحات  -

تاریخ انتشار 2017